Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Note

The fire resistance is only valid when wall is used as partition with only one side exposed to fire.

Attention: REI 90 (from inside) in Germany possible with 2x12,5mm gypsum plaster board type DF/gypsum fibre board

e.g. Cross laminated timer:
thickness 5-ply at least, surface layer at least 19mm

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
A 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
B - variable insulation material
C 70,0 spruce wood batten mounted on resilient Clips (60/60) 0,120 50 450 1,600 D
D solid glued wood (e.g. cross laminated timber) 0,130 50 500 1,600 D
E 70,0 spruce wood batten mounted on resilient Clips (60/60) 0,120 50 450 1,600 D
F - variable insulation material
G 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
G 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
twmxxo04a-02 B
D
F
60,0
97,0
60,0
mineral wool [040; 11; <1000°C]
solid glued wood
mineral wool [040; 11; <1000°C]
262,0 90 0,27 adequate 53 (-5,-13) 32,34 74,9

Last update 02.08.2023/hfa.eco2soft