compartment wall solid wood construction, without dry lining, single-layer, other surface
The fire resistance is only valid when wall is used as partition with only one side exposed to fire.
Cross laminated timber: 3-ply at least, surface layer at least 25 mm
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 36,0 | gypsum plaster board type DF (2x18 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
A | 36,0 | gypsum fibre board (2x18 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
B | - variable insulation material | ||||||
C | 70,0 | spruce wood batten mounted on resilient clips (60/60; e=625) | 0,120 | 50 | 450 | 1,600 | D |
D | 80,0 | cross laminated timber | 0,130 | 50 | 500 | 1,600 | D |
E | 70,0 | spruce wood batten mounted on resilient Clips (60/60; e=625) | 0,120 | 50 | 450 | 1,600 | D |
F | - variable insulation material | ||||||
G | 36,0 | gypsum plaster board type DF (2x18 mm) or | 0,250 | 10 | 800 | 1,050 | A2 |
G | 36,0 | gypsum fibre board (2x18 mm) | 0,320 | 21 | 1000 | 1,100 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 28.06.2018/hfa.plb