Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 12,5 gypsum plaster boards Rigips RF or 0,250 10 900 1,050 A2
A 12,5 gypsum fibre board Rigidur H 0,350 19 1200 1,100 A2
B 90,0 cross laminated timber BBS 3 layer 0,130 50 470 1,600 D
C 30,0 gypsum fibre board Rigidur H (2x15 mm) 0,350 19 1200 1,100 A2
D 50,0 mineral wool [040; 50] 0,040 1 50 1,030 A1
E 50,0 air layer 1 1 1,008
F 30,0 gypsum fibre board Rigidur H (2x15 mm) 0,350 19 1200 1,100 A2
G 90,0 cross laminated timber BBS 3 layer 0,130 50 470 1,600 D
H 12,5 gypsum fibre board Rigidur H 0,350 19 1200 1,100 A2
H 12,5 gypsum plaster boards Rigips RF or 0,250 10 900 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) OI3Kon m [kg/m²]
twmxxo05a-00 365,0 60 0,30 adequate 70 (-2,-8) 28,00 181,7

Source: Saint-Gobain Rigips Austria GesmbH

Last update 28.09.2017/hfa.plb