compartment wall solid wood construction, without dry lining, double-layer, other surface
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 | |
A | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 | |
B | 70,0 | spruce wood batten mounted on resilient clips | 0,120 | 50 | 450 | 1,600 | D |
C | 50,0 | mineral wool [040; 13] | 0,040 | 1 | 13 | 1,030 | A2 |
D | cross laminated timber 3- or 5-ply (e.g. ≥ 78mm; 3-ply at least, surface layer at least 25mm) | 0,130 | 50 | 500 | 1,600 | D | |
E | impact sound absorbing subflooring MW-T | 0,035 | 1 | 68 | 1,030 | A1 | |
F | cross laminated timber 3- or 5-ply (e.g. ≥ 78mm; 3-ply at least, surface layer at least 25mm) | 0,130 | 50 | 500 | 1,600 | D | |
G | 50,0 | mineral wool [040; 13] | 0,040 | 1 | 13 | 1,030 | A2 |
H | 70,0 | spruce wood batten mounted on resilient clips | 0,120 | 50 | 450 | 1,600 | D |
I | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 | |
I | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Last update 27.06.2018/hfa.plb