Scope

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 15,0 plaster 0,700 10 1300 1,000 A1
B 50,0 Heraklith BM 0,090 2-5 370 2,000 B
C construction timber (60/100; e=625) 0,120 50 450 1,600 D
D - variable insulation material
E 50,0 Heraklith BM 0,090 2-5 370 2,000 B
F 15,0 plaster 0,700 10 1300 1,000 A1

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) OI3Kon m [kg/m²]
twrxxo01-00 D 120,0 Heralan KP 250,0 60 0,25 adequate 60 (-1,-6) -10,50 82,4

Source: Knauf Insulation GmbH