Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A Rigips Riduro 2x...mm 0,250 4-10 1000 1,050 A2
B 100,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
C - variable insulation material
D mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
E 100,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
F - variable insulation material
G Rigips Riduro 2x...mm 0,250 4-10 1000 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
twrxxo09b-00 A
C
D
F
G
25,0
100,0
10,0
100,0
25,0
Rigips Riduro
ISOVER Multi-Kombi Holzrahmenfilz
mineral wool [040; ≥16; <1000°C]
ISOVER Multi-Kombi Holzrahmenfilz
Rigips Riduro
Fill the separating joint > 10 mm with mineral wool or seal off floor by floor 90 0,18 62 25,51 63,0
twrxxo09b-01 A
C
D
F
G
30,0
100,0
10,0
100,0
30,0
Rigips Riduro
ISOVER Multi-Kombi Holzrahmenfilz
mineral wool [040; ≥16; <1000°C]
ISOVER Multi-Kombi Holzrahmenfilz
Rigips Riduro
Fill the separating joint > 10 mm with mineral wool or seal off floor by floor 90 0,18 68 27,47 73,0

Source: Saint-Gobain Austria GmbH

Last update 02.08.2023/hfa.eco2soft