compartment wall solid wood construction, without dry lining, double-layer, other surface
Fire performance | REI | 90 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 14,95 kN/m
Classified by IBS
|
||
Thermal performance | U | 0,29 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 72 dB (-2; -8) |
Ln,w (Cl) | ||
Rating by IFT
|
||
Mass per unit area | m | 204,2 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 25,0 | gypsum plaster boards Rigips RF (2x12,5 mm) or | 0,250 | 10 | 900 | 1,050 | A2 |
A | 25,0 | gypsum fibre board Rigidur H (2x12,5 mm) | 0,350 | 19 | 1200 | 1,100 | A2 |
B | 90,0 | cross laminated timber BBS 125 3 layer | 0,130 | 50 | 470 | 1,600 | D |
C | 30,0 | gypsum fibre board Rigidur H (2x15 mm) | 0,350 | 19 | 1200 | 1,100 | A2 |
D | 50,0 | mineral wool [040; 50] | 0,040 | 1 | 50 | 1,030 | A1 |
E | 50,0 | air layer | 1 | 1 | 1,008 | ||
F | 30,0 | gypsum fibre board Rigidur H (2x15 mm) | 0,350 | 19 | 1200 | 1,100 | A2 |
G | 90,0 | cross laminated timber BBS 125 3 layer | 0,130 | 50 | 470 | 1,600 | D |
H | 25,0 | gypsum plaster boards Rigips RF (2x12,5 mm) or | 0,250 | 10 | 900 | 1,050 | A2 |
H | 25,0 | gypsum fibre board Rigidur H (2x12,5 mm) | 0,350 | 19 | 1200 | 1,100 | A2 |
ΔOI3 | 88,8 |
---|---|
Calculated by HFA
|
Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP [kg CO2 Äqv.] |
AP [kg SO2 Äqv.] |
EP [kg PO4 Äqv.] |
ODP [kg R11 Äqv.] |
POCP [kg Ethen Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
A1 - A3 | -73,044 | 0,413 | 0,144 | 8,23e-6 | 0,032 | 503,653 | 1166,400 | 1670,053 | 1346,779 | 29,297 | 1376,076 |