Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 90
maximum ceiling height = 3 m; maximum load Ed,fi = 14,95 kN/m  
Classified by IBS  
Thermal performance U 0,29 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 72 dB (-2; -8)
Ln,w (Cl)
Rating by IFT  
Mass per unit area m 204,2 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 25,0 gypsum plaster boards Rigips RF (2x12,5 mm) or 0,250 10 900 1,050 A2
A 25,0 gypsum fibre board Rigidur H (2x12,5 mm) 0,350 19 1200 1,100 A2
B 90,0 cross laminated timber BBS 125 3 layer 0,130 50 470 1,600 D
C 30,0 gypsum fibre board Rigidur H (2x15 mm) 0,350 19 1200 1,100 A2
D 50,0 mineral wool [040; 50] 0,040 1 50 1,030 A1
E 50,0 air layer 1 1 1,008
F 30,0 gypsum fibre board Rigidur H (2x15 mm) 0,350 19 1200 1,100 A2
G 90,0 cross laminated timber BBS 125 3 layer 0,130 50 470 1,600 D
H 25,0 gypsum plaster boards Rigips RF (2x12,5 mm) or 0,250 10 900 1,050 A2
H 25,0 gypsum fibre board Rigidur H (2x12,5 mm) 0,350 19 1200 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 88,8
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -73,044 0,413 0,144 8,23e-6 0,032 503,653 1166,400 1670,053 1346,779 29,297 1376,076

Source: Saint-Gobain Rigips Austria GesmbH

Last update 07.07.2021/hfa.plb