Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI 60
apply to each individual load-bearing wall; the whole wall: EI90; maximum ceiling height = 3 m; maximum load Ed,fi = 19,2 kN/m
Classified by HFA  
Classified by HFA  
Fire performance Germany
Classification: F60  
Load Ed,fi according to the German certification document
Proof: manufacturer-specific  
Thermal performance U 0,19 W/(m2K)
Diffusion adequate
Calculated by TUM  
Acoustic performance Rw (C;Ctr) 59 dB (-2; -9)
Ln,w (Cl)
Rating by Müller-BBM  
Mass per unit area m 96,1 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
A 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
B 15,0 OSB 0,130 200 600 1,700 D
C 100,0 construction timber (60/100; e=*) 0,120 50 450 1,600 D
D 100,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
E 15,0 OSB 0,130 200 600 1,700 D
F 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
G 20,0 mineral wool [040; ≥16; <1000°C] 0,040 1 16 1,030 A1
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
I 15,0 OSB 0,130 200 600 1,700 D
J 100,0 construction timber (60/100; e=*) 0,120 50 450 1,600 D
K 100,0 Wood fibre insulation [039; 45] 0,039 1-2 45 2,100 E
L 15,0 OSB 0,130 200 600 1,700 D
M 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
M 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

Built-in renewable materials 53,2 kg
Share of renewable materials of total weight 56,27 %
Global warming potential (GWP-T) -52,735 kgCO2Äqv.
Energy use of Primary Energy 747,4 MJ
Share of renewable Primary Energy 22,2 %
∑ΔOI3 31,6
Calculated by HFA  

Global warming potential Share of renewable Primary Energy Resources
Lifecycle
Phase
GWP-F
[kgCO2Äqv.]
GWP-B
[kgCO2Äqv.]
GWP-T
[kgCO2Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
A1 - A3 34,734 -87,468 -52,735 165,678 891,543 1057,221 581,763 57,369 639,132 0,143 0,061 3.2118674E-6 0,028

Database GaBi (ÖKOBAUDAT)

Built-in renewable materials 56,5 kg
Biogenic carbon 85,3 kgCO2Äqv.
Energy use of Primary Energy 1433,2 MJ
Share of renewable Primary Energy 30,2 %
Calculated by TUM  

Resources
Lifecycle
Phase
GWP
[kgCO2Äqv.]
AP
[kgSO2Äqv.]
EP
[kgPO4Äqv.]
ODP
[kgR11Äqv.]
POCP
[kgEthenÄqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -78,044 0,168 0,031 7.18E-7 0,058 428,036 1313,812 1742,617 948,763 64,665 1013,520
C1 - C4 124,984 0,005 0,001 1.07E-7 0,001 3,002 -1293,075 -1290,076 30,967 -60,897 -29,930
A1 - C4 48,389 0,179 0,034 8.54E-7 0,059 432,556 21,772 455,095 1000,648 3,976 1004,720

Last update 02.08.2023/hfa.eco2soft