Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 5,0 plaster external wall cladding, e.g. clapboard facade 1,000 10-35 2000 1,130 A1
B 12,0 plaster base board (expanded glass granulate board) battens vertical (30/60); ventilation 0,120 10-15 500 1,000
C 40,0 spruce wood 0,120 50 450 1,600 D
D wind barrier sd ≤ 0,3m 1000
E 24,0 planking spruce wood 0,120 50 450 1,600 D
F 280,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
G - variable insulation material
H 100,0 cross laminated timber 5-ply 0,130 50 500 1,600 D
I 30,0 spruce wood (60/60) vertical on resilient clips, e=626 0,120 50 450 1,600 D
J 22,0 clay board or 0,353 5-10 1450 1,100 A1
K 5,0 0,810 10 1700 0,930 A1

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awmhpi02a-00 G 280,0 Cellulose fibre [038; 50] 90 from inside
60 from outside
0,13 adequate 47 (-1,-7) 38,66 126,2

Last update 05.08.2024/hfa.plb