Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration
solid wood construction
Standard configuration

Note

Cross laminated timber:
Variation 00-01: d ≥ 94,0; at least 3-layers, top layer at least 30mm; variation 02: d ≥ 85,0; at least 5-layers, top layer at least 17 mm

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 20,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens 0,120 50 450 1,600 D
C vapour-permeable membrane sd ≤ 0,3m
D 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
E - variable insulation material
F cross laminated timber 0,130 50 500 1,600 D
G - variable building material

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awmoho05a-00 E
F
G
200,0
100,0
wood-fibre insulation board [0,040; R=160]
cross laminated timber
without gypsum board lining
359,0 G: without plaster board 60 from inside
90 from outside
0,17 adequate 43 40,66 107,4
awmoho05a-01 E
F
G
200,0
100,0
mineral wool [035; 130; ≥1000°C]
cross laminated timber
without gypsum board lining
359,0 G=without plaster board 60 from inside
90 from outside
0,15 adequate 41 86,73 101,4
awmoho05a-02 E
F
G
200,0
90,0
12,5
mineral wool [035; 130; ≥1000°C]
cross laminated timber
gypsum plaster board type DF / gypsum fibre board
362,5 F= at least 5-layers cross laminated timber 60 from inside
60 from outside
0,15 adequate 43 87,55 96,9

Last update 02.08.2023/nu.ge