Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 6,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board [046; 200] 0,046 3-7 200 2,100 E
C 160,0 construction timber (60/160; e=625) 0,120 50 450 1,600 D
D 160,0 mineral wool [035; 18] 0,035 1 18 1,030 A1
E 90,0 cross laminated timber BBS 3 layer 0,130 50 470 1,600 D
F 70,0 spruce wood battens (60/60; e=625) mounted on resilient clips 0,120 50 450 1,600 D
G 50,0 mineral wool [040; 18] 0,040 1 18 1,030 A1
H 15,0 gypsum fibre board Rigidur H 0,350 19 1200 1,100 A2
H 15,0 gypsum plaster boards Rigips RF or 0,250 10 900 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) ΔOI3 m [kg/m²]
awmopi02a-00 401,0 60 from inside 0,14 adequate 55 (-7,-15) 50,66 93,8

Source: Saint-Gobain Rigips Austria GesmbH

Last update 07.05.2020/hfa.plb