Skip to main content
Regional validity

Scope

solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 6,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 softboard [046; 200] 0,046 3-7 200 2,100 E
C 160,0 construction timber (60/160; e=625) 0,120 50 450 1,600 D
D 160,0 mineral wool [035; 18] 0,035 1 18 1,030 A1
E cross laminated timber BBS 3 layer 0,130 50 470 1,600 D
F gypsum plaster boards Rigips RF or 0,250 10 900 1,050 A2
F gypsum fibre board Rigidur H 0,350 19 1200 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) ΔOI3 m [kg/m²]
awmopo02a-00 E
F
90,0
15,0
cross laminated timber BBS
gypsum plaster boards Rigips RF
331,0 BBS 3 layer 60 from inside 0,17 adequate 45 (-2,-8) 42,63 90,1
awmopo02a-01 E
F
90,0
cross laminated timber BBS
gypsum plaster boards Rigips RF
316,0 BBS 3 layer; without gypsum board lining 30 from inside 0,17 adequate 45 (-2,-8) 40,30 76,6
awmopo02a-02 E
F
100,0
15,0
cross laminated timber BBS
gypsum plaster boards Rigips RF
341,0 BBS 5 layer 90 from inside 0,16 adequate 45 (-2,-8) 44,28 103,8

Source: Saint-Gobain Rigips Austria GesmbH

Last update 07.05.2020/hfa.plb