Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C wind barrier 1000
D 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 10,0 gypsum fibre board 0,320 21 1000 1,100 A2
H vapour barrier sd≥ 2m 1000
I spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
J - variable building material
K 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
K 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhhi01a-00 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
284,0 e=625 45 from inside
30 from outside
0,22 adequate 50 (-3,-10) 22,47 43,6
awrhhi01a-01 E
F
I
J
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
244,0 e=625 45 from inside
30 from outside
0,27 adequate 49 (-2,-9) 19,83 40,9
awrhhi01a-02 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
284,0 e=625; J=without insulation 45 from inside
30 from outside
0,26 adequate 49 (-3,-10) 20,07 42,9
awrhhi01a-03 E
F
I
J
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
324,0 e=625 45 from inside
30 from outside
0,18 adequate 51 (-3,-10) 25,12 45,9
awrhhi01a-04 E
F
I
J
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
364,0 e=625 45 from inside
30 from outside
0,16 adequate 52 (-3,-10) 27,77 48,4
awrhhi01a-05 E
F
I
J
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
364,0 e=625 45 from inside
30 from outside
0,16 adequate 51 (-3,-10) 27,40 49,0
awrhhi01a-06 E
F
I
J
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
404,0 e=625 45 from inside
30 from outside
0,14 adequate 52 (-3,-10) 30,05 51,5
awrhhi01a-07 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
284,0 e=625 45 from inside
30 from outside
0,20 adequate 51 (-3,-10) 44,91 49,5
awrhhi01a-08 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
284,0 e=625 60 from inside
60 from outside
0,22 adequate 50 (-3,-10) 28,26 46,5
awrhhi01a-09 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [0,040; R=55]
spruce wood
cellulose fibre [040; E]
284,0 e=625 45 from inside
30 from outside
0,22 adequate 50 (-3,-10) 15,64 50,4
awrhhi01a-10 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
284,0 e=625 45 from inside
30 from outside
0,24 adequate 50 (-3,-10) 15,95 43,3
awrhhi01a-11 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
284,0 e=400 45 from inside
30 from outside
0,23 adequate 50 (-3,-10) 22,07 47,6

Last update 02.08.2023/hfa.eco2soft