Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C wind barrier 1000
D 20,0 gypsum fibre board (2x10 mm) 0,320 21 1000 1,100 A2
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
H vapour barrier sd≥ 2m 1000
I spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
J - variable building material
K 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
K 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) OI3Kon m [kg/m²]
awrhhi01b-00 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
296,5 e=625 60 from inside
60 from outside
0,22 adequate 51 (-2,-8) -5,24 55,9
awrhhi01b-01 E
F
I
J
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
256,5 e=625 60 from inside
60 from outside
0,26 adequate 50 (-1,-7) -7,76 53,4
awrhhi01b-02 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
296,5 e=625; J=without insulation 60 from inside
60 from outside
0,25 adequate 50 (-2,-8) -7,85 55,4
awrhhi01b-03 E
F
I
J
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
336,5 e=625 60 from inside
60 from outside
0,18 adequate 52 (-2,-8) -2,72 58,4
awrhhi01b-04 E
F
I
J
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
376,5 e=625 60 from inside
60 from outside
0,16 adequate 53 (-2,-8) -0,19 60,9
awrhhi01b-05 E
F
I
J
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
376,5 e=625 60 from inside
60 from outside
0,16 adequate 52 (-2,-8) -0,47 61,5
awrhhi01b-06 E
F
I
J
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
416,5 e=625 60 from inside
60 from outside
0,14 adequate 53 (-2,-8) 2,05 64,0
awrhhi01b-07 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
296,5 e=625 60 from inside
60 from outside
0,20 adequate 52 (-2,-8) 21,34 62,0
awrhhi01b-08 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
296,5 e=625 60 from inside
60 from outside
0,22 adequate 51 (-2,-8) -2,71 59,0
awrhhi01b-09 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [0,040; R=55]
spruce wood
cellulose fibre [040; E]
296,5 e=625 60 from inside
60 from outside
0,22 adequate 51 (-2,-8) -11,87 62,9
awrhhi01b-10 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=16]
296,5 e=625 60 from inside
60 from outside
0,24 adequate 51 (-2,-8) -14,11 55,9
awrhhi01b-11 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
296,5 e=400 60 from inside
60 from outside
0,23 adequate 51 (-2,-8) -5,91 60,1

Last update 23.08.2017/hfa.plb