Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D
E - variable insulation material
F 15,0 OSB 0,130 200 600 1,700 D
G - variable building material
H - variable building material
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhhi04a-00 D
E
G
H
160,0
160,0
40,0
40,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
296,5 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) 23,03 41,8
awrhhi04a-01 D
E
G
H
120,0
120,0
40,0
40,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
256,5 60 from inside
30 from outside
0,25 adequate 49 (-2,-9) 20,38 39,3
awrhhi04a-02 D
E
G
H
160,0
160,0
40,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
spruce wood cross battens (a=400) resp. battens offset
air layer
296,5 60 from inside
30 from outside
0,24 adequate 49 (-3,-10) 20,63 41,3
awrhhi04a-03 D
E
G
H
200,0
200,0
40,0
40,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
336,5 60 from inside
30 from outside
0,18 adequate 51 (-3,-10) 25,68 44,3
awrhhi04a-04 D
E
G
H
240,0
240,0
40,0
40,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
376,5 60 from inside
30 from outside
0,16 adequate 52 (-3,-10) 28,32 46,8
awrhhi04a-05 D
E
G
H
200,0
200,0
80,0
80,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
376,5 60 from inside
30 from outside
0,15 adequate 51 (-3,-10) 27,96 47,4
awrhhi04a-06 D
E
G
H
240,0
240,0
80,0
80,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
416,5 60 from inside
30 from outside
0,14 adequate 52 (-3,-10) 30,61 49,9
awrhhi04a-07 D
E
G
H
160,0
160,0
40,0
40,0
construction timber (60/..; e=625)
mineral wool [035; 50; <1000°C]
spruce wood cross battens (a=400) resp. battens offset
mineral wool [035; 50; <1000°C]
296,5 60 from inside
30 from outside
0,19 adequate 51 (-3,-10) 45,46 47,9
awrhhi04a-08 D
E
G
H
160,0
160,0
40,0
40,0
construction timber (60/..; e=625)
mineral wool [040; 33; ≥1000°C]
spruce wood cross battens (a=400) ≥ 40mm
mineral wool [040; 33; ≥1000°C]
296,5 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) 28,82 58,9
awrhhi04a-09 D
E
G
H
160,0
160,0
40,0
40,0
construction timber (60/..; e=625)
Cellulose fibre [040; 50]
spruce wood cross battens (a=400) ≥ 40mm
Cellulose fibre [040; 50]
296,5 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) 16,20 62,0
awrhhi04a-10 D
E
G
H
160,0
160,0
40,0
40,0
construction timber (60/..; e=625)
sheep wool [0,041; R=26]
spruce wood cross battens (a=400) resp. battens offset
sheep wool [0,041; R=26]
296,5 60 from inside
30 from outside
0,23 adequate 50 (-3,-10) 16,51 41,8
awrhhi04a-11 D
E
G
H
160,0
160,0
40,0
40,0
construction timber (60/..; e=400)
mineral wool [040; ≥16; <1000°C]
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
296,5 60 from inside
30 from outside
0,22 adequate 50 (-3,-10) 22,63 46,0
awrhhi04a-12 D
E
G
H
160,0
160,0
40,0
40,0
construction timber (60/..; e=625)
Wood fibre insulation [039; 45]
spruce wood cross battens (a=400) ≥ 40mm
Wood fibre insulation [039; 45]
296,5 dry lining ≥ 40 mm 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) 17,77 61,1
awrhhi04a-13 D
E
G
H
200,0
200,0
40,0
40,0
construction timber (60/..; e=625)
mineral wool [040; 30; ≥1000°C]
spruce wood cross battens (a=400) ≥ 40mm
mineral wool [040; 30; ≥1000°C]
336,5 dry lining ≥ 40 mm 60 from inside
30 from outside
0,18 adequate 51 (-3,-10) 27,10 61,2
awrhhi04a-14 D
E
G
H
200,0
200,0
40,0
40,0
construction timber (60/..; e=625)
Cellulose fibre [040; 50]
spruce wood cross battens (a=400) ≥ 40mm
Cellulose fibre [040; 50]
336,5 dry lining ≥ 40 mm 60 from inside
30 from outside
0,18 adequate 51 (-3,-10) 17,46 65,5
awrhhi04a-15 D
E
G
H
200,0
200,0
40,0
40,0
construction timber (60/..; e=625)
Wood fibre insulation [039; 45]
spruce wood cross battens (a=400) ≥ 40mm
Wood fibre insulation [039; 45]
336,5 dry lining ≥ 40 mm 60 from inside
30 from outside
0,18 adequate 51 (-3,-10) 19,35 64,4
awrhhi04a-16 D
E
G
H
240,0
240,0
40,0
40,0
construction timber (60/..; e=625)
mineral wool [040; 30; ≥1000°C]
spruce wood cross battens (a=400) ≥ 40mm
mineral wool [040; 30; ≥1000°C]
376,5 dry lining ≥ 40 mm 60 from inside
30 from outside
0,15 adequate 52 (-3,-10) 29,99 64,0
awrhhi04a-17 D
E
G
H
240,0
240,0
40,0
40,0
construction timber (60/..; e=625)
Cellulose fibre [040; 50]
spruce wood cross battens (a=400) ≥ 40mm
Cellulose fibre [040; 50]
376,5 dry lining ≥ 40 mm 60 from inside
30 from outside
0,15 adequate 52 (-3,-10) 18,72 69,0
awrhhi04a-18 D
E
G
H
240,0
240,0
40,0
40,0
construction timber (60/..; e=625)
Wood fibre insulation [039; 45]
spruce wood cross battens (a=400) ≥ 40mm
Wood fibre insulation [039; 45]
376,5 dry lining ≥ 40 mm 60 from inside
30 from outside
0,15 adequate 52 (-3,-10) 20,93 67,8

Last update 02.08.2023/hfa.eco2soft