Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C 12,0 OSB 0,130 200 600 1,700 D
D construction timber (60/..; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F 15,0 OSB 0,130 200 600 1,700 D
G vapour barrier sd≥ 10m 1000
H spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I - variable building material
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) OI3Kon m [kg/m²]
awrhhi05a-00 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
293,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) 8,40 40,7
awrhhi05a-01 D
E
H
I
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
253,5 e=625 60 from inside
30 from outside
0,26 adequate 49 (-2,-9) 5,88 38,2
awrhhi05a-02 D
E
H
I
160,0
160,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
293,5 e=625; I=without insulation 60 from inside
30 from outside
0,25 adequate 49 (-3,-10) 6,14 40,2
awrhhi05a-03 D
E
H
I
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
333,5 e=625 60 from inside
30 from outside
0,18 adequate 51 (-3,-10) 10,93 43,2
awrhhi05a-04 D
E
H
I
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
373,5 e=625 60 from inside
30 from outside
0,16 adequate 52 (-3,-10) 13,45 45,7
awrhhi05a-05 D
E
H
I
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
373,5 e=625 60 from inside
30 from outside
0,16 adequate 51 (-3,-10) 13,17 46,3
awrhhi05a-06 D
E
H
I
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
413,5 e=625 60 from inside
30 from outside
0,14 adequate 52 (-3,-10) 15,69 48,8
awrhhi05a-07 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
293,5 e=625 60 from inside
30 from outside
0,19 adequate 51 (-3,-10) 33,73 46,8
awrhhi05a-08 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
293,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) 10,93 43,7
awrhhi05a-09 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [0,040; R=55]
spruce wood
cellulose fibre [040; E]
293,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) 1,77 51,3
awrhhi05a-10 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
293,5 e=625 60 from inside
30 from outside
0,23 adequate 50 (-3,-10) 0,44 40,7
awrhhi05a-11 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
293,5 e=400 60 from inside
30 from outside
0,22 adequate 50 (-3,-10) 8,07 44,9

Last update 23.08.2017/hfa.plb