Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C wind barrier 1000
D 25,0 planking spruce wood 0,120 50 450 1,600 D
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 25,0 planking spruce wood 0,120 50 450 1,600 D
H vapour barrier sd≥ 5m 1000
I spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
J - variable building material
K 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
K 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhhi06a-00 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
316,5 e=625 60 from inside
30 from outside
0,20 adequate 51 (-3,-10) 17,64 49,4
awrhhi06a-01 E
F
I
J
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
276,5 e=625 60 from inside
30 from outside
0,24 adequate 50 (-2,-9) 14,95 46,9
awrhhi06a-02 E
F
I
J
160,0
160,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
316,5 e=625; J=without insulation 60 from inside
30 from outside
0,23 adequate 50 (-3,-10) 15,20 48,9
awrhhi06a-03 E
F
I
J
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
356,5 e=625 60 from inside
30 from outside
0,17 adequate 51 (-3,-10) 20,33 51,9
awrhhi06a-04 E
F
I
J
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
396,5 e=625 60 from inside
30 from outside
0,15 adequate 52 (-3,-10) 23,03 54,4
awrhhi06a-05 E
F
I
J
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
396,5 e=625 60 from inside
30 from outside
0,15 adequate 51 (-3,-10) 22,66 55,0
awrhhi06a-06 E
F
I
J
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
436,5 e=625 60 from inside
30 from outside
0,13 adequate 52 (-3,-10) 25,35 57,5
awrhhi06a-07 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
316,5 e=625 60 from inside
30 from outside
0,18 adequate 52 (-3,-10) 40,47 55,5
awrhhi06a-08 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
316,5 e=625 60 from inside
30 from outside
0,20 adequate 51 (-3,-10) 25,65 52,5
awrhhi06a-09 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [040; E]
spruce wood
cellulose fibre [040; E]
316,5 e=625 60 from inside
30 from outside
0,20 adequate 51 (-3,-10) 10,16 60,0
awrhhi06a-10 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
316,5 e=625 60 from inside
30 from outside
0,22 adequate 51 (-3,-10) 11,22 49,4
awrhhi06a-11 E
F
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
316,5 e=400 60 from inside
30 from outside
0,21 adequate 51 (-3,-10) 17,23 53,6

Last update 02.08.2023/hfa.eco2soft