Register of building materials used for this application, cross-section (from outside to inside)
|
Thickness [mm] |
Building material |
Thermal performance |
Reaction to fire |
λ |
μ min – max |
ρ |
c |
A |
24,0 |
larch wood external wall cladding |
0,155 |
150 |
600 |
1,600 |
D |
B |
24,0 |
spruce wood battens - ventilation |
0,120 |
50 |
450 |
1,600 |
D |
C |
24,0 |
spruce wood cross battens |
0,120 |
50 |
450 |
1,600 |
D |
D |
|
wind barrier |
|
|
1000 |
|
|
E |
60,0 |
wood-fibre insulation board [045; 140] |
0,045 |
2-5 |
140 |
2,100 |
E |
F |
|
construction timber (60/..; e=*) |
0,120 |
50 |
450 |
1,600 |
D |
G |
|
- variable insulation material |
|
|
|
|
|
H |
15,0 |
OSB (sealed with airtight tape) |
0,130 |
200 |
600 |
1,700 |
D |
I |
|
spruce wood cross battens (a=400) or battens offset) |
0,120 |
50 |
450 |
1,600 |
D |
J |
|
- variable building material |
|
|
|
|
|
K |
12,5 |
gypsum plaster board type DF or |
0,250 |
10 |
800 |
1,050 |
A2 |
K |
12,5 |
gypsum fibre board |
0,320 |
21 |
1000 |
1,100 |
A2 |
Variations of building components
|
Thickness of layer |
Note |
Fire performance |
Thermal performance |
Acoustic performance |
Eco Sustainability |
Mass |
|
Thickness [mm] |
Building material |
Σ |
REI |
U [W/(m²K)] |
Diffusion |
Rw (C,Ctr) |
ΔOI3 |
m [kg/m²] |
awrhhi07a-00 |
F G I J |
160,0 160,0 40,0 40,0 |
construction timber mineral wool [040; ≥16; <1000°C] spruce wood mineral wool [040; ≥16; <1000°C] |
359,5 |
e=625 |
60 from inside 30 from outside |
0,19 |
adequate |
50 (-3,-10)
| 24,89 |
40,4 |
awrhhi07a-02 |
F G I J |
160,0 160,0 40,0 40,0 |
construction timber mineral wool [040; ≥16; <1000°C] spruce wood air layer |
359,5 |
e=625; J =without insulation |
60 from inside 30 from outside |
0,22 |
adequate |
49 (-3,-10)
| 22,44 |
39,9 |
awrhhi07a-03 |
F G I J |
200,0 200,0 40,0 40,0 |
construction timber mineral wool [040; ≥16; <1000°C] spruce wood mineral wool [040; ≥16; <1000°C] |
399,5 |
e=625 |
60 from inside 30 from outside |
0,16 |
adequate |
51 (-3,-10)
| 27,58 |
42,9 |
awrhhi07a-04 |
F G I J |
240,0 240,0 40,0 40,0 |
construction timber mineral wool [040; ≥16; <1000°C] spruce wood mineral wool [040; ≥16; <1000°C] |
439,5 |
e=625 |
60 from inside 30 from outside |
0,14 |
adequate |
52 (-3,-10)
| 30,27 |
45,4 |
awrhhi07a-05 |
F G I J |
200,0 200,0 80,0 80,0 |
construction timber mineral wool [040; ≥16; <1000°C] spruce wood mineral wool [040; ≥16; <1000°C] |
439,5 |
e=625 |
60 from inside 30 from outside |
0,14 |
adequate |
51 (-3,-10)
| 29,91 |
46,0 |
awrhhi07a-06 |
F G I J |
240,0 240,0 80,0 80,0 |
construction timber mineral wool [040; ≥16; <1000°C] spruce wood mineral wool [040; ≥16; <1000°C] |
479,5 |
e=625 |
60 from inside 30 from outside |
0,13 |
adequate |
52 (-3,-10)
| 32,60 |
48,5 |
awrhhi07a-07 |
F G I J |
160,0 160,0 40,0 40,0 |
construction timber mineral wool [035; 50; <1000°C] spruce wood mineral wool [035; 50; <1000°C] |
359,5 |
e=625 |
60 from inside 30 from outside |
0,17 |
adequate |
51 (-3,-10)
| 47,71 |
46,5 |
awrhhi07a-08 |
F G I J |
160,0 160,0 40,0 40,0 |
construction timber mineral wool [038; ≥33; ≥1000°C] spruce wood mineral wool [038; ≥33; ≥1000°C] |
359,5 |
e=625 |
60 from inside 30 from outside |
0,19 |
adequate |
50 (-3,-10)
| 32,90 |
43,5 |
awrhhi07a-09 |
F G I J |
160,0 160,0 40,0 40,0 |
construction timber cellulose fibre [040; E] spruce wood cellulose fibre [0,040; R=55] |
359,5 |
e=625 |
60 from inside 30 from outside |
0,19 |
adequate |
50 (-3,-10)
| 17,40 |
47,4 |
awrhhi07a-10 |
F G I J |
160,0 160,0 40,0 40,0 |
construction timber sheep wool [0,041; R=26] spruce wood sheep wool [0,041; R=26] |
359,5 |
e=625 |
60 from inside 30 from outside |
0,21 |
adequate |
50 (-3,-10)
| 19,00 |
40,4 |
awrhhi07a-11 |
F G I J |
160,0 160,0 40,0 40,0 |
construction timber mineral wool [040; ≥16; <1000°C] spruce wood mineral wool [040; ≥16; <1000°C] |
359,5 |
e=400 |
60 from inside 30 from outside |
0,20 |
adequate |
50 (-3,-10)
| 24,48 |
44,6 |
Last update 25.01.2021/hfa.plb