Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 24,0 spruce wood battens - ventilation 0,120 50 450 1,600 D
C 24,0 spruce wood cross battens 0,120 50 450 1,600 D
D wind barrier 1000
E 30,0 wood-fibre insulation board [0,045; R=150] 0,045 2-5 150 2,500 E
F construction timber (60/..; e=*) 0,120 50 450 1,600 D
G - variable insulation material
H 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
I spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
J - variable building material
K 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
K 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) OI3Kon m [kg/m²]
awrhhi07a-00 F
G
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
329,5 e=625 60 from inside
30 from outside
0,19 adequate 50 (-3,-10) -1,87 40,4
awrhhi07a-01 F
G
I
J
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
289,5 e=625 60 from inside
30 from outside
0,22 adequate 49 (-2,-9) -4,39 37,9
awrhhi07a-02 F
G
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
329,5 e=625; J =without insulation 60 from inside
30 from outside
0,22 adequate 49 (-3,-10) -4,14 39,9
awrhhi07a-03 F
G
I
J
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
369,5 e=625 60 from inside
30 from outside
0,16 adequate 51 (-3,-10) 0,65 42,9
awrhhi07a-04 F
G
I
J
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
409,5 e=625 60 from inside
30 from outside
0,14 adequate 52 (-3,-10) 3,17 45,4
awrhhi07a-05 F
G
I
J
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
409,5 e=625 60 from inside
30 from outside
0,14 adequate 51 (-3,-10) 2,90 46,0
awrhhi07a-06 F
G
I
J
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
449,5 e=625 60 from inside
30 from outside
0,13 adequate 52 (-3,-10) 5,42 48,5
awrhhi07a-07 F
G
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
329,5 e=625 60 from inside
30 from outside
0,17 adequate 51 (-3,-10) 23,46 46,5
awrhhi07a-08 F
G
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
329,5 e=625 60 from inside
30 from outside
0,19 adequate 50 (-3,-10) 0,65 43,5
awrhhi07a-09 F
G
I
J
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [040; E]
spruce wood
cellulose fibre [0,040; R=55]
329,5 e=625 60 from inside
30 from outside
0,19 adequate 50 (-3,-10) -8,50 47,4
awrhhi07a-10 F
G
I
J
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
329,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) -10,74 40,4
awrhhi07a-11 F
G
I
J
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
329,5 e=400 60 from inside
30 from outside
0,20 adequate 50 (-3,-10) -2,20 44,6

Last update 23.08.2017/hfa.plb