Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C wind barrier 1000
D 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I - variable insulation material or air layer in type 02
J 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
J 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhhi08a-00 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
289,0 e=625 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) 23,97 42,9
awrhhi08a-01 E
F
H
I
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
249,0 e=625 60 from inside
30 from outside
0,26 adequate 49 (-2,-9) 21,28 40,4
awrhhi08a-02 E
F
H
I
160,0
160,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
nur Lattung
289,0 e=625; I=without insulation 60 from inside
30 from outside
0,25 adequate 49 (-3,-10) 21,53 42,4
awrhhi08a-03 E
F
H
I
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
329,0 e=625 60 from inside
30 from outside
0,18 adequate 51 (-3,-10) 26,66 45,4
awrhhi08a-04 E
F
H
I
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
369,0 e=625 60 from inside
30 from outside
0,16 adequate 52 (-3,-10) 29,35 47,9
awrhhi08a-05 E
F
H
I
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
369,0 e=625 60 from inside
30 from outside
0,16 adequate 51 (-3,-10) 28,99 48,5
awrhhi08a-06 E
F
H
I
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
409,0 e=625 60 from inside
30 from outside
0,14 adequate 52 (-3,-10) 31,68 51,0
awrhhi08a-07 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
289,0 e=625 60 from inside
30 from outside
0,19 adequate 51 (-3,-10) 46,80 49,0
awrhhi08a-08 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
289,0 e=625 60 from inside
60 from outside
0,21 adequate 50 (-3,-10) 31,98 46,0
awrhhi08a-09 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [040; E]
spruce wood
cellulose fibre [040; E]
289,0 e=625 60 from inside
30 from outside
0,21 adequate 50 (-3,-10) 16,49 49,9
awrhhi08a-10 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
289,0 e=625 60 from inside
30 from outside
0,24 adequate 50 (-3,-10) 17,55 42,9
awrhhi08a-11 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
289,0 e=400 60 from inside
30 from outside
0,23 adequate 50 (-3,-10) 23,56 47,1

Last update 02.08.2023/hfa.eco2soft