Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C wind barrier 1000
D 20,0 gypsum fibre board (2x10 mm) 0,320 21 1000 1,100 A2
E - variable insulation material
F construction timber (60..; e=*) 0,120 50 450 1,600 D
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I - variable insulation material or air layer in type 02
J 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2
J 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhhi08b-00 E
F
H
I
160,0
160,0
40,0
40,0
mineral wool [040; ≥16; <1000°C]
construction timber
spruce wood
mineral wool [040; ≥16; <1000°C]
304,0 e=625 60 from inside
60 from outside
0,21 adequate 52 (-2,-8) 26,92 57,9
awrhhi08b-01 E
F
H
I
120,0
120,0
40,0
40,0
mineral wool [040; ≥16; <1000°C]
construction timber
spruce wood
mineral wool [040; ≥16; <1000°C]
264,0 e=625 60 from inside
60 from outside
0,26 adequate 51 (-1,-7) 24,23 55,4
awrhhi08b-02 E
F
H
I
160,0
160,0
40,0
mineral wool [040; ≥16; <1000°C]
construction timber
spruce wood
nur Lattung
304,0 e=625; I=without insulation 60 from inside
60 from outside
0,25 adequate 51 (-2,-8) 24,48 57,4
awrhhi08b-03 E
F
H
I
200,0
200,0
40,0
40,0
mineral wool [040; ≥16; <1000°C]
construction timber
spruce wood
mineral wool [040; ≥16; <1000°C]
344,0 e=625 60 from inside
60 from outside
0,18 adequate 53 (-2,-8) 29,61 60,4
awrhhi08b-04 E
F
H
I
240,0
240,0
40,0
40,0
mineral wool [040; ≥16; <1000°C]
construction timber
spruce wood
mineral wool [040; ≥16; <1000°C]
384,0 e=625 60 from inside
60 from outside
0,16 adequate 54 (-2,-8) 32,30 62,9
awrhhi08b-05 E
F
H
I
200,0
200,0
80,0
80,0
mineral wool [040; ≥16; <1000°C]
construction timber
spruce wood
mineral wool [040; ≥16; <1000°C]
384,0 e=625 60 from inside
60 from outside
0,16 adequate 53 (-2,-8) 31,94 63,5
awrhhi08b-06 E
F
H
I
240,0
240,0
80,0
80,0
mineral wool [040; ≥16; <1000°C]
construction timber
spruce wood
mineral wool [040; ≥16; <1000°C]
424,0 e=625 60 from inside
60 from outside
0,14 adequate 54 (-2,-8) 34,63 66,0
awrhhi08b-07 E
F
H
I
160,0
160,0
40,0
40,0
mineral wool [035; 50; <1000°C]
construction timber
spruce wood
mineral wool [035; 50; <1000°C]
304,0 e=625 60 from inside
60 from outside
0,19 adequate 53 (-2,-8) 49,75 64,0
awrhhi08b-08 E
F
H
I
160,0
160,0
40,0
40,0
mineral wool [038; ≥33; ≥1000°C]
construction timber
spruce wood
mineral wool [038; ≥33; ≥1000°C]
304,0 e=625 60 from inside
60 from outside
0,21 adequate 52 (-2,-8) 34,93 61,0
awrhhi08b-09 E
F
H
I
160,0
160,0
40,0
40,0
cellulose fibre [040; E]
construction timber
spruce wood
cellulose fibre [040; E]
304,0 e=625 60 from inside
60 from outside
0,21 adequate 52 (-2,-8) 19,44 64,9
awrhhi08b-10 E
F
H
I
160,0
160,0
40,0
40,0
sheep wool [0,041; R=26]
construction timber
spruce wood
sheep wool [0,041; R=26]
304,0 e=625 60 from inside
60 from outside
0,23 adequate 52 (-2,-8) 20,50 57,9
awrhhi08b-11 E
F
H
I
160,0
160,0
40,0
40,0
mineral wool [040; ≥16; <1000°C]
construction timber
spruce wood
mineral wool [040; ≥16; <1000°C]
304,0 e=400 60 from inside
60 from outside
0,23 adequate 52 (-2,-8) 26,51 62,1

Last update 02.08.2023/hfa.eco2soft