Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C 15,0 OSB 0,130 200 600 1,700 D
D construction timber (60/..; e=625) 0,120 50 450 1,600 D
E - variable insulation material
F vapour barrier sd≥ 4m 1000
G 40,0 spruce wood cross battens 40/60mm (a=400) 0,120 50 450 1,600 D
H 40,0 air layer 1 1 1,008
I 16,0 Kronospan OSB-Firestop 0,110 150-170 660 1,700 B

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhhi13a-00 D
E
200,0
200,0
construction timber (60/..; e=625)
mineral wool [038; ≥33; ≥1000°C]
60 from inside
30 from outside
0,19 adequate 48 (-3,-10) 28,14 53,9
awrhhi13a-01 D
E
240,0
240,0
construction timber (60/..; e=625)
mineral wool [038; ≥33; ≥1000°C]
60 from inside
30 from outside
0,17 adequate 49 (-3,-10) 31,97 56,8
awrhhi13a-02 D
E
200,0
200,0
construction timber (60/..; e=625)
Cellulose fibre [040; 50]
30 from inside
30 from outside
0,20 adequate 48 (-3,-10) 15,23 57,0

Source: KRONOSPAN OSB, spol. s r. o.

Last update 02.08.2023/hfa.eco2soft