external wall timber frame construction, ventilated, with dry lining, with cladding
| Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
|---|---|---|---|---|---|---|---|
| λ | μ min – max | ρ | c | ||||
| A | 19,0 | larch wood external wall cladding (tongue and groove) | 0,120 | 50 | 450 | 1,600 | D |
| B | 30,0 | spruce wood cross battens (≥30/50) | 0,120 | 50 | 450 | 1,600 | D |
| C | 30,0 | spruce wood battens (≥30/50) - ventilation | 0,120 | 50 | 450 | 1,600 | D |
| D | vapour-permeable membrane sd ≤ 0,1m | ||||||
| E | 15,0 | fibreboard (MDF) | 0,140 | 11 | 600 | 1,700 | D |
| F | 160,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
| G | - variable insulation material | ||||||
| H | 8,0 | Funderplan Biofaser (sealed with airtight tape) | 0,180 | 185 | 1000 | 1,700 | D |
| I | 40,0 | spruce wood battens vertical | 0,120 | 50 | 450 | 1,600 | D |
| J | - variable building material | ||||||
| K | 15,0 | gypsum plaster board type DF or | 0,250 | 10 | 800 | 1,050 | A2 |
| K | 15,0 | gypsum fibre board | 0,320 | 21 | 1000 | 1,100 | A2 |
| Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] | ||
Source: FunderMax GmbH
Last update 20.06.2024/hfa.plb