Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C wind barrier 1000
D 16,0 particleboard 0,130 50-100 700 1,700 D
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 16,0 particleboard 0,130 50-100 700 1,700 D
H vapour barrier sd≥ 5m 1000
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhho02a-00 E
F
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
258,5 e=625 60 from inside
30 from outside
0,26 adequate 47 (-2,-8) 24,83 37,1
awrhho02a-01 E
F
120,0
120,0
construction timber
mineral wool [040; ≥16; <1000°C]
218,5 e=625 60 from inside
30 from outside
0,33 adequate 46 (-2,-8) 22,16 34,6
awrhho02a-02 E
F
200,0
200,0
construction timber
mineral wool [040; ≥16; <1000°C]
298,5 e=625 60 from inside
30 from outside
0,22 adequate 48 (-2,-8) 27,45 39,6
awrhho02a-03 E
F
240,0
240,0
construction timber
mineral wool [040; ≥16; <1000°C]
338,5 e=625 60 from inside
30 from outside
0,18 adequate 49 (-2,-8) 30,10 42,1
awrhho02a-04 E
F
160,0
160,0
construction timber
mineral wool [035; 50; <1000°C]
258,5 e=625 60 from inside
30 from outside
0,24 adequate 48 (-2,-8) 42,99 42,0
awrhho02a-05 E
F
160,0
160,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
258,5 e=625 60 from inside
30 from outside
0,26 adequate 47 (-2,-8) 29,52 39,5
awrhho02a-06 E
F
160,0
160,0
construction timber
cellulose fibre [0,040; R=55]
258,5 e=625 60 from inside
30 from outside
0,26 adequate 47 (-2,-8) 19,30 42,7
awrhho02a-07 E
F
160,0
160,0
construction timber
sheep wool [0,041; R=26]
258,5 e=625 60 from inside
30 from outside
0,29 adequate 47 (-2,-8) 19,96 37,1
awrhho02a-08 E
F
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
258,5 e=400 60 from inside
30 from outside
0,28 adequate 47 (-2,-8) 24,43 41,2

Last update 02.08.2023/hfa.eco2soft