Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C 15,0 OSB 0,130 200 600 1,700 D
D construction timber (60/..; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F 15,0 OSB 0,130 200 600 1,700 D
G vapour barrier sd≥ 10m 1000
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhho03a-00 D
E
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
256,5 e=625 60 from inside
30 from outside
0,26 adequate 47 (-2,-8) 20,00 37,6
awrhho03a-01 D
E
120,0
120,0
construction timber
mineral wool [040; ≥16; <1000°C]
216,5 e=625 60 from inside
30 from outside
0,33 adequate 46 (-2,-8) 17,35 35,1
awrhho03a-02 D
E
200,0
200,0
construction timber
mineral wool [040; ≥16; <1000°C]
296,5 e=625 60 from inside
30 from outside
0,21 adequate 48 (-2,-8) 22,64 40,1
awrhho03a-03 D
E
240,0
240,0
construction timber
mineral wool [040; ≥16; <1000°C]
336,5 e=625 60 from inside
30 from outside
0,18 adequate 49 (-2,-8) 25,29 42,6
awrhho03a-04 D
E
160,0
160,0
construction timber
mineral wool [035; 50; <1000°C]
256,5 e=625 60 from inside
30 from outside
0,24 adequate 48 (-2,-8) 38,16 42,6
awrhho03a-05 D
E
160,0
160,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
256,5 e=625 60 from inside
30 from outside
0,26 adequate 47 (-2,-8) 24,68 40,1
awrhho03a-06 D
E
160,0
160,0
construction timber
cellulose fibre [0,040; R=55]
256,5 e=625 60 from inside
30 from outside
0,26 adequate 47 (-2,-8) 14,46 46,2
awrhho03a-07 D
E
160,0
160,0
construction timber
sheep wool [0,041; R=26]
256,5 e=625 60 from inside
30 from outside
0,28 adequate 47 (-2,-8) 15,12 37,7
awrhho03a-08 D
E
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
256,5 e=400 60 from inside
30 from outside
0,28 adequate 47 (-2,-8) 19,59 41,8

Last update 02.08.2023/hfa.eco2soft