Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D
E - variable insulation material
F vapour barrier sd≥ 1m 1000
G 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2
G 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhho05a-00 D
E
160,0
160,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
244,0 30 from inside
30 from outside
0,27 adequate 45 (-2,-8) 19,06 29,1
awrhho05a-01 D
E
120,0
120,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
204,0 30 from inside
30 from outside
0,34 adequate 44 (-2,-8) 16,42 26,6
awrhho05a-02 D
E
200,0
200,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
284,0 30 from inside
30 from outside
0,22 adequate 46 (-2,-8) 21,71 31,6
awrhho05a-03 D
E
240,0
240,0
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
324,0 30 from inside
30 from outside
0,19 adequate 47 (-2,-8) 25,06 34,1
awrhho05a-04 D
E
160,0
160,0
construction timber (60/..; e=625)
mineral wool [035; 50; <1000°C]
244,0 30 from inside
30 from outside
0,24 adequate 46 (-2,-8) 37,23 34,0
awrhho05a-05 D
E
160,0
160,0
construction timber (60/..; e=625)
mineral wool [040; 33; ≥1000°C]
244,0 30 from inside
30 from outside
0,26 adequate 45 (-2,-8) 23,75 48,2
awrhho05a-06 D
E
160,0
160,0
construction timber (60/..; e=625)
Cellulose fibre [040; 50]
244,0 30 from inside
30 from outside
0,27 adequate 45 (-2,-8) 13,53 34,7
awrhho05a-07 D
E
160,0
160,0
construction timber (60/..; e=625)
sheep wool [0,041; R=26]
244,0 30 from inside
30 from outside
0,29 adequate 45 (-2,-8) 14,19 29,1
awrhho05a-08 D
E
160,0
160,0
construction timber (60/..; e=400)
mineral wool [040; ≥16; <1000°C]
244,0 30 from inside
30 from outside
0,29 adequate 45 (-2,-8) 18,66 33,3
awrhho05a-09 D
E
160,0
160,0
construction timber (60/..; e=625)
Wood fibre insulation [039; 45]
244,0 30 from inside
30 from outside
0,26 adequate 45 (-2,-8) 14,81 49,9
awrhho05a-10 D
E
200,0
200,0
construction timber (60/..; e=625)
mineral wool [040; 30; ≥1000°C]
284,0 30 from inside
30 from outside
0,21 adequate 46 (-2,-8) 32,23 50,5
awrhho05a-11 D
E
200,0
200,0
construction timber (60/..; e=625)
Wood fibre insulation [039; 45]
284,0 30 from inside
30 from outside
0,21 adequate 46 (-2,-8) 16,39 53,3
awrhho05a-12 D
E
240,0
240,0
construction timber (60/..; e=625)
mineral wool [040; 30; ≥1000°C]
324,0 30 from inside
30 from outside
0,18 adequate 47 (-2,-8) 25,80 53,4
awrhho05a-13 D
E
240,0
240,0
construction timber (60/..; e=625)
Wood fibre insulation [039; 45]
324,0 30 from inside
30 from outside
0,18 adequate 47 (-2,-8) 17,97 56,6

Last update 02.08.2023/hfa.eco2soft