Register of building materials used for this application, cross-section (from outside to inside)
|
Thickness [mm] |
Building material |
Thermal performance |
Reaction to fire |
λ |
μ min – max |
ρ |
c |
A |
24,0 |
larch wood external wall cladding |
0,155 |
150 |
600 |
1,600 |
D |
B |
30,0 |
spruce wood battens offset (30/50; 30/80) - ventilation |
0,120 |
50 |
450 |
1,600 |
D |
C |
|
wind barrier |
|
|
1000 |
|
|
D |
20,0 |
gypsum fibre board (2x10 mm) |
0,320 |
21 |
1000 |
1,100 |
A2 |
E |
|
construction timber (60/..; e=*) |
0,120 |
50 |
450 |
1,600 |
D |
F |
|
- variable insulation material |
|
|
|
|
|
G |
15,0 |
OSB (sealed with airtight tape) |
0,130 |
200 |
600 |
1,700 |
D |
H |
15,0 |
gypsum fibre board or |
0,320 |
21 |
1000 |
1,100 |
A2 |
H |
15,0 |
gypsum plaster board type DF |
0,250 |
10 |
800 |
1,050 |
A2 |
Variations of building components
|
Thickness of layer |
Note |
Fire performance |
Thermal performance |
Acoustic performance |
Eco Sustainability |
Mass |
|
Thickness [mm] |
Building material |
Σ |
REI |
U [W/(m²K)] |
Diffusion |
Rw (C,Ctr) |
OI3Kon |
m [kg/m²] |
awrhho08b-00 |
E F |
160,0 160,0 |
construction timber mineral wool [040; ≥16; <1000°C] |
264,0 |
e=625 |
60 from inside 30 from outside |
0,26 |
adequate |
49 (-2,-7)
| -3,17 |
54,9 |
awrhho08b-01 |
E F |
120,0 120,0 |
construction timber mineral wool [040; ≥16; <1000°C] |
224,0 |
e=625 |
60 from inside 30 from outside |
0,33 |
adequate |
48 (-2,-7)
| -5,69 |
52,4 |
awrhho08b-02 |
E F |
200,0 200,0 |
construction timber mineral wool [040; ≥16; <1000°C] |
304,0 |
e=625 |
60 from inside 30 from outside |
0,22 |
adequate |
50 (-2,-7)
| -0,65 |
57,4 |
awrhho08b-03 |
E F |
240,0 240,0 |
construction timber mineral wool [040; ≥16; <1000°C] |
344,0 |
e=625 |
60 from inside 30 from outside |
0,18 |
adequate |
51 (-2,-7)
| 1,88 |
59,9 |
awrhho08b-04 |
E F |
160,0 160,0 |
construction timber mineral wool [035; 50; <1000°C] |
264,0 |
e=625 |
60 from inside 30 from outside |
0,24 |
adequate |
50 (-2,-7)
| 17,34 |
59,8 |
awrhho08b-05 |
E F |
160,0 160,0 |
construction timber mineral wool [038; ≥33; ≥1000°C] |
264,0 |
e=625 |
60 from inside 30 from outside |
0,26 |
adequate |
49 (-2,-7)
| -1,12 |
57,3 |
awrhho08b-06 |
E F |
160,0 160,0 |
construction timber cellulose fibre [0,040; R=55] |
264,0 |
e=625 |
60 from inside 30 from outside |
0,26 |
adequate |
49 (-2,-7)
| -8,54 |
60,5 |
awrhho08b-07 |
E F |
160,0 160,0 |
construction timber sheep wool [0,041; R=26] |
264,0 |
e=625 |
60 from inside 30 from outside |
0,29 |
adequate |
49 (-2,-7)
| -10,35 |
54,9 |
awrhho08b-08 |
E F |
160,0 160,0 |
construction timber mineral wool [040; ≥16; <1000°C] |
264,0 |
e=400 |
60 from inside 30 from outside |
0,28 |
adequate |
49 (-2,-7)
| -3,50 |
59,1 |
Last update 23.08.2017/hfa.plb