Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 30,0 spruce wood battens offset (30/50; 30/80) - ventilation 0,120 50 450 1,600 D
C wind barrier 1000
D 20,0 gypsum fibre board (2x10 mm) 0,320 21 1000 1,100 A2
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H 15,0 gypsum fibre board or 0,320 21 1000 1,100 A2
H 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhho08b-00 E
F
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
264,0 e=625 60 from inside
60 from outside
0,26 adequate 49 (-2,-7) 23,54 54,9
awrhho08b-01 E
F
120,0
120,0
construction timber
mineral wool [040; ≥16; <1000°C]
224,0 e=625 60 from inside
60 from outside
0,33 adequate 48 (-2,-7) 20,89 52,4
awrhho08b-02 E
F
200,0
200,0
construction timber
mineral wool [040; ≥16; <1000°C]
304,0 e=625 60 from inside
60 from outside
0,22 adequate 50 (-2,-7) 26,19 57,4
awrhho08b-03 E
F
240,0
240,0
construction timber
mineral wool [040; ≥16; <1000°C]
344,0 e=625 60 from inside
60 from outside
0,18 adequate 51 (-2,-7) 28,83 59,9
awrhho08b-04 E
F
160,0
160,0
construction timber
mineral wool [035; 50; <1000°C]
264,0 e=625 60 from inside
60 from outside
0,24 adequate 50 (-2,-7) 41,70 59,8
awrhho08b-05 E
F
160,0
160,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
264,0 e=625 60 from inside
60 from outside
0,26 adequate 49 (-2,-7) 28,23 57,3
awrhho08b-06 E
F
160,0
160,0
construction timber
cellulose fibre [0,040; R=55]
264,0 e=625 60 from inside
60 from outside
0,26 adequate 49 (-2,-7) 18,01 60,5
awrhho08b-07 E
F
160,0
160,0
construction timber
sheep wool [0,041; R=26]
264,0 e=625 60 from inside
60 from outside
0,29 adequate 49 (-2,-7) 18,67 54,9
awrhho08b-08 E
F
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
264,0 e=400 60 from inside
60 from outside
0,28 adequate 49 (-2,-7) 23,14 59,1

Last update 02.08.2023/hfa.eco2soft