external wall timber frame construction, ventilated, without dry lining, with cladding
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 24,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 30,0 | spruce wood battens offset (30/50; 30/80) - ventilation | 0,120 | 50 | 450 | 1,600 | D |
C | wind barrier | 1000 | |||||
D | 15,0 | Rigips Riduro | 0,250 | 4-10 | 1000 | 1,050 | A2 |
E | 160,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
F | - variable insulation material | ||||||
G | vapour barrier sd≥ 2m | 1000 | |||||
H | 15,0 | Rigips Riduro | 0,250 | 4-10 | 1000 | 1,050 | A2 |
Thickness of layer | Fire performance | Thermal performance | Acoustic performance | Eco Sustainability | Mass | |||||
---|---|---|---|---|---|---|---|---|---|---|
Thickness [mm] | Building material | Σ | REI | U [W/(m²K)] | Diffusion | Rw (C,Ctr) [dB] | ΔOI3 | m [kg/m²] |
Source: Saint-Gobain Austria GmbH
Last update 02.08.2023/hfa.eco2soft