timber frame construction
Cross-section of standard configuration

Note

According to OIB-RL 2 (Austria) is for ventilated and insulated facades (from building class 2) an insulation material with minimum Euroclass D required.

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding (closed) 0,155 150 600 1,600 D
B 30,0 spruce wood cross battens (≥30/50) 0,120 50 450 1,600 D
C 30,0 spruce wood battens - ventilation (≥30/50) 0,120 50 450 1,600 D
D 35,0 STEICOuniversal dry [050; 210] 0,050 3 210 2,100 E
E 160,0 STEICOjoist mit Furnierschichtholzgurten (60/39) und Hartfasersteg (60/160; e=625)
F - variable insulation material
G STEICOmulti membra 5 sd 5m E
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrhho14a-00 F 160,0 STEICOzell [039; 40] 291,5 30 from inside
30 from outside
0,21 adequate 45 (-2,-8) 21,82 45,2
awrhho14a-01 F 160,0 STEICOflex [037; 60] 291,5 30 from inside
30 from outside
0,20 adequate 45 (-2,-8) 20,49 48,2

Source: Steico SE