Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 24,0 spruce wood cross battens 0,120 50 450 1,600 D
C 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H spruce wood battens offset mounted on resilient clips 0,120 50 450 1,600 D
I - variable insulation material or air layer in type 02
J 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
J 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awrohi01a-00 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
340,5 e=625 60 from inside
30 from outside
0,18 adequate 54 (-3,-9) 27,79 71,5
awrohi01a-01 E
F
H
I
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
300,5 e=625 60 from inside
30 from outside
0,21 adequate 53 (-3,-9) 25,15 69,0
awrohi01a-02 E
F
H
I
160,0
160,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
nur Lattung
340,5 e=625; I=without insulation 60 from inside
30 from outside
0,20 adequate 53 (-3,-9) 25,28 70,9
awrohi01a-03 E
F
H
I
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
380,5 e=625 60 from inside
30 from outside
0,15 adequate 55 (-3,-9) 30,44 73,9
awrohi01a-04 E
F
H
I
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
420,5 e=625 60 from inside
30 from outside
0,14 adequate 56 (-3,-9) 33,08 76,4
awrohi01a-05 E
F
H
I
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
420,5 e=625 60 from inside
30 from outside
0,13 adequate 55 (-3,-9) 32,72 76,1
awrohi01a-06 E
F
H
I
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
460,5 e=625 60 from inside
30 from outside
0,12 adequate 56 (-3,-9) 35,37 78,3
awrohi01a-07 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
340,5 e=625 60 from inside
30 from outside
0,16 adequate 55 (-3,-9) 50,41 77,6
awrohi01a-08 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
340,5 e=625 60 from inside
30 from outside
0,18 adequate 54 (-3,-9) 33,63 74,5
awrohi01a-09 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [040; E]
spruce wood
cellulose fibre [040; E]
338,0 e=625 60 from inside
30 from outside
0,18 adequate 54 (-3,-9) 20,90 78,5
awrohi01a-10 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
340,5 e=625 60 from inside
30 from outside
0,19 adequate 54 (-3,-9) 21,72 71,5
awrohi01a-11 E
F
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
340,5 e=400 60 from inside
30 from outside
0,19 adequate 54 (-3,-9) 27,39 76,5

Last update 02.08.2023/hfa.eco2soft