Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 24,0 spruce wood cross battens 0,120 50 450 1,600 D
C 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
D 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
H 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
H 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awroho01a-00 E
F
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
300,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-2,-7) 25,19 70,8
awroho01a-01 E
F
120,0
120,0
construction timber
mineral wool [040; ≥16; <1000°C]
260,5 e=625 60 from inside
30 from outside
0,26 adequate 49 (-2,-7) 22,55 68,3
awroho01a-02 E
F
200,0
200,0
construction timber
mineral wool [040; ≥16; <1000°C]
340,5 e=625 60 from inside
30 from outside
0,18 adequate 51 (-2,-7) 27,84 73,3
awroho01a-03 E
F
240,0
240,0
construction timber
mineral wool [040; ≥16; <1000°C]
380,5 e=625 60 from inside
30 from outside
0,16 adequate 52 (-2,-7) 30,48 75,8
awroho01a-04 E
F
160,0
160,0
construction timber
mineral wool [035; 50; <1000°C]
300,5 e=625 60 from inside
30 from outside
0,20 adequate 51 (-2,-7) 43,35 75,7
awroho01a-05 E
F
160,0
160,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
300,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-2,-7) 29,88 73,2
awroho01a-06 E
F
160,0
160,0
construction timber
cellulose fibre [040; E]
300,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-2,-7) 19,66 76,4
awroho01a-07 E
F
160,0
160,0
construction timber
sheep wool [0,041; R=26]
300,5 e=625 60 from inside
30 from outside
0,23 adequate 50 (-2,-7) 20,32 70,8
awroho01a-08 E
F
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
300,5 e=400 60 from inside
30 from outside
0,22 adequate 50 (-2,-7) 24,79 74,9

Last update 02.08.2023/hfa.eco2soft