Register of building materials used for this application, cross-section
(from outside to inside)
|
Thickness [mm] |
Building material |
Thermal performance |
Reaction to fireklasse EN |
λ |
μ min – max |
ρ |
c |
A |
24,0
|
larch wood
external wall cladding
|
0,155
|
150
|
600
|
1,600
|
D
|
B |
50,0
|
spruce wood
cross battens
|
0,120
|
50
|
450
|
1,600
|
D
|
C |
40,0
|
softboard [045; 250] - rigid underlay
|
0,045
|
5
|
250
|
2,100
|
E
|
D |
15,0
|
fibreboard (MDF)
|
0,140
|
11
|
600
|
1,700
|
D
|
E |
|
construction timber
(60/..; e=*)
|
0,120
|
50
|
450
|
1,600
|
D
|
F |
|
- variable insulation material
|
|
|
|
|
|
G |
15,0
|
OSB
(sealed with airtight tape)
|
0,130
|
200
|
600
|
1,700
|
D
|
H |
12,5
|
gypsum fibre board
or
|
0,320
|
21
|
1000
|
1,100
|
A2
|
H |
12,5
|
gypsum plaster board type DF
|
0,250
|
10
|
800
|
1,050
|
A2
|
Variations of building components
|
Thickness of layer |
Note |
Fire performance |
Thermal performance |
Acoustic performance |
Eco Sustainability |
Mass |
|
Thickness [mm] |
Building material |
Σ |
REI |
U [W/(m²K)] |
Diffusion |
Rw (C,Ctr) [dB] |
ΔOI3 |
m [kg/m²] |
awroho02a-00
|
E
F
|
160,0
160,0
|
construction timber
mineral wool [040; ≥16; <1000°C]
|
276,5
|
e=625
|
60
from inside
30
from outside
|
0,20
|
adequate
|
50
(-2,-7)
|
28,15
|
61,5
|
awroho02a-01
|
E
F
|
120,0
120,0
|
construction timber
mineral wool [040; ≥16; <1000°C]
|
236,5
|
e=625
|
60
from inside
30
from outside
|
0,24
|
adequate
|
49
(-2,-7)
|
25,50
|
59,0
|
awroho02a-02
|
E
F
|
200,0
200,0
|
construction timber
mineral wool [040; ≥16; <1000°C]
|
316,5
|
e=625
|
60
from inside
30
from outside
|
0,17
|
adequate
|
51
(-2,-7)
|
30,79
|
64,0
|
awroho02a-03
|
E
F
|
240,0
240,0
|
construction timber
mineral wool [040; ≥16; <1000°C]
|
356,5
|
e=625
|
60
from inside
30
from outside
|
0,15
|
adequate
|
52
(-2,-7)
|
33,44
|
66,5
|
awroho02a-04
|
E
F
|
160,0
160,0
|
construction timber
mineral wool [035; 50; <1000°C]
|
276,5
|
e=625
|
60
from inside
30
from outside
|
0,19
|
adequate
|
51
(-2,-7)
|
46,31
|
66,4
|
awroho02a-05
|
E
F
|
160,0
160,0
|
construction timber
mineral wool [038; ≥33; ≥1000°C]
|
276,5
|
e=625
|
60
from inside
30
from outside
|
0,20
|
adequate
|
50
(-2,-7)
|
32,83
|
63,9
|
awroho02a-06
|
E
F
|
160,0
160,0
|
construction timber
cellulose fibre [040; E]
|
276,5
|
e=625
|
60
from inside
30
from outside
|
0,20
|
adequate
|
50
(-2,-7)
|
22,61
|
67,1
|
awroho02a-07
|
E
F
|
160,0
160,0
|
construction timber
sheep wool [0,041; R=26]
|
276,5
|
e=625
|
60
from inside
30
from outside
|
0,22
|
adequate
|
50
(-2,-7)
|
23,27
|
61,5
|
awroho02a-08
|
E
F
|
160,0
160,0
|
construction timber
mineral wool [040; ≥16; <1000°C]
|
276,5
|
e=400
|
60
from inside
30
from outside
|
0,21
|
adequate
|
50
(-2,-7)
|
27,74
|
66,1
|
Last update 02.08.2023/hfa.eco2soft