Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 24,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 65,0 spruce wood cross battens 0,120 50 450 1,600 D
C 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
D 16,0 particleboard 0,130 50-100 700 1,700 D
E construction timber (60/..; e=*) 0,120 50 450 1,600 D
F - variable insulation material
G 12,0 particleboard 0,130 50-100 700 1,700 D
H vapour barrier sd≥ 10m 1000
I 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
I 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awroho03a-00 E
F
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
289,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-2,-7) 25,45 66,6
awroho03a-01 E
F
120,0
120,0
construction timber
mineral wool [040; ≥16; <1000°C]
249,5 e=625 60 from inside
30 from outside
0,26 adequate 49 (-2,-7) 22,80 64,1
awroho03a-02 E
F
200,0
200,0
construction timber
mineral wool [040; ≥16; <1000°C]
329,5 e=625 60 from inside
30 from outside
0,18 adequate 51 (-2,-7) 28,09 69,1
awroho03a-03 E
F
240,0
240,0
construction timber
mineral wool [040; ≥16; <1000°C]
369,5 e=625 60 from inside
30 from outside
0,16 adequate 52 (-2,-7) 30,74 71,6
awroho03a-04 E
F
160,0
160,0
construction timber
mineral wool [035; 50; <1000°C]
289,5 e=625 60 from inside
30 from outside
0,20 adequate 51 (-2,-7) 43,61 71,5
awroho03a-05 E
F
160,0
160,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
289,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-2,-7) 30,14 69,2
awroho03a-06 E
F
160,0
160,0
construction timber
cellulose fibre [0,040; R=55]
289,5 e=625 60 from inside
30 from outside
0,21 adequate 50 (-2,-7) 19,91 72,3
awroho03a-07 E
F
160,0
160,0
construction timber
sheep wool [0,041; R=26]
289,5 e=625 60 from inside
30 from outside
0,23 adequate 50 (-2,-7) 20,58 66,6
awroho03a-08 E
F
160,0
160,0
construction timber
mineral wool [040; ≥16; <1000°C]
289,5 e=400 60 from inside
30 from outside
0,23 adequate 50 (-2,-7) 25,04 71,2

Last update 02.08.2023/hfa.eco2soft