Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 10,0 plaster 1,000 10-35 2000 1,130 A1
B 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
C construction timber (60/..; e=*) 0,120 50 450 1,600 D
D - variable insulation material
E 18,0 OSB 0,130 200 600 1,700 D
F spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
G - variable insulation material or air layer in type 02
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropi05a-00 C
D
F
G
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
284,5 e=625 60 from inside
60 from outside
0,19 adequate 52 (-3,-10) 27,19 58,6
awropi05a-01 C
D
F
G
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
244,5 e=625 60 from inside
60 from outside
0,23 adequate 52 (-3,-10) 24,54 56,1
awropi05a-02 C
D
F
G
160,0
160,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
nur Lattung
284,5 e=625; G=without insulation 60 from inside
60 from outside
0,22 adequate 52 (-3,-10) 24,72 58,0
awropi05a-03 C
D
F
G
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
324,5 e=625 60 from inside
60 from outside
0,16 adequate 53 (-3,-10) 29,84 61,1
awropi05a-04 C
D
F
G
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
364,5 e=625 60 from inside
60 from outside
0,15 adequate 54 (-3,-10) 32,48 63,6
awropi05a-05 C
D
F
G
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
364,5 e=625 60 from inside
60 from outside
0,15 adequate 53 (-3,-10) 32,21 64,1
awropi05a-06 C
D
F
G
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
404,5 e=625 60 from inside
60 from outside
0,13 adequate 54 (-3,-10) 34,86 66,6
awropi05a-07 C
D
F
G
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
284,5 e=625 60 from inside
60 from outside
0,18 adequate 53 (-3,-10) 49,75 64,7
awropi05a-08 C
D
F
G
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
284,5 e=625 60 from inside
60 from outside
0,19 adequate 52 (-3,-10) 33,01 61,6
awropi05a-09 C
D
F
G
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [040; E]
spruce wood
cellulose fibre [040; E]
284,5 e=625 60 from inside
60 from outside
0,19 adequate 52 (-3,-10) 20,32 65,6
awropi05a-10 C
D
F
G
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
284,5 e=625 60 from inside
60 from outside
0,21 adequate 52 (-3,-10) 21,14 58,6
awropi05a-11 C
D
F
G
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
284,5 e=400 60 from inside
60 from outside
0,20 adequate 52 (-3,-10) 26,79 62,7

Last update 02.08.2023/hfa.eco2soft