Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 4,0 plaster 1,000 10-35 2000 1,130 A1
B - variable building material
C 15,0 OSB 0,130 200 600 1,700 D
D (60/..; e=*)
E - variable insulation material
F 15,0 OSB 0,130 200 600 1,700 D
G - variable building material
H - variable building material cross battens (a=400) or battens offset)
I - variable insulation material or air layer in type 02
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropi06a-00 B
D
E
G
H
I
50,0
160,0
160,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
296,5 e=625 60 from inside
30 from outside
0,17 adequate 45 (-3,-6) 30,26 48,5
awropi06a-01 B
D
E
G
H
I
50,0
120,0
120,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
256,5 e=625 60 from inside
30 from outside
0,20 adequate 44 (-3,-6) 27,62 46,0
awropi06a-02 B
D
E
G
H
I
50,0
160,0
160,0

40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
nur Lattung
296,5 e=625 ; I=without insulation 60 from inside
30 from outside
0,19 adequate 45 (-3,-6) 27,79 48,0
awropi06a-03 B
D
E
G
H
I
50,0
200,0
200,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
336,5 e=625 60 from inside
30 from outside
0,15 adequate 46 (-3,-6) 32,91 51,0
awropi06a-04 B
D
E
G
H
I
50,0
240,0
240,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
376,5 e=625 60 from inside
30 from outside
0,13 adequate 48 (-3,-6) 35,56 53,5
awropi06a-05 B
D
E
G
H
I
50,0
200,0
200,0

80,0
80,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
376,5 e=625 60 from inside
30 from outside
0,13 adequate 46 (-3,-6) 35,28 54,1
awropi06a-06 B
D
E
G
H
I
50,0
240,0
240,0

80,0
80,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
416,5 e=625 60 from inside
30 from outside
0,12 adequate 48 (-3,-6) 37,93 56,6
awropi06a-07 B
D
E
G
H
I
50,0
160,0
160,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [035; 50; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) ≥ 40mm
mineral wool [035; 50; <1000°C]
296,5 e=625 60 from inside
30 from outside
0,16 adequate 46 (-3,-6) 52,82 54,6
awropi06a-08 B
D
E
G
H
I
50,0
160,0
160,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [038; ≥33; ≥1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [038; ≥33; ≥1000°C]
296,5 e=625 60 from inside
30 from outside
0,17 adequate 45 (-3,-6) 36,09 51,6
awropi06a-09 B
D
E
G
H
I
50,0
160,0
160,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
cellulose fibre [040; E]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
cellulose fibre [0,040; R=55]
296,5 e=625 60 from inside
30 from outside
0,17 adequate 45 (-3,-6) 23,39 55,5
awropi06a-10 B
D
E
G
H
I
50,0
160,0
160,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
sheep wool [0,041; R=26]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
sheep wool [0,041; R=26]
296,5 e=625 60 from inside
30 from outside
0,18 adequate 45 (-3,-6) 24,21 48,5
awropi06a-11 B
D
E
G
H
I
50,0
160,0
160,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=400)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
296,5 e=400 60 from inside
30 from outside
0,18 adequate 45 (-3,-6) 29,86 52,6
awropi06a-12 B
D
E
G
H
I
160,0
160,0
160,0

40,0
40,0
Polystyrene EPS-F [0,040]
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
406,5 e=625 60 from inside
30 from outside
0,11 adequate 45 (-3,-6) 40,66 50,4
awropi06a-13 B
D
E
G
H
I
50,0
160,0
160,0

40,0
40,0
Elasticized polystyrene FS
construction timber (60/..; e=625)
mineral wool [040; ≥16; <1000°C]
vapour barrier sd≥ 23m
spruce wood cross battens (a=400) resp. battens offset
mineral wool [040; ≥16; <1000°C]
296,5 e=625 60 from inside
30 from outside
0,17 adequate 47 (-3,-6) 30,26 48,5
awropi06a-14 B
D
E
G
H
I
100,0
200,0
200,0

30,0
30,0

construction timber (60/..; e=625)
mineral wool [040; 30; ≥1000°C]
vapour barrier sd≥ 50m
resilient channel a=625 vertical
mineral wool [035; 20; ≥1000°C]
376,5 60 from inside
30 from outside
0,12 adequate 51 (-6,-13) 42,15 54,0

Last update 02.08.2023/hfa.eco2soft