Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 10,0 plaster 1,000 10-35 2000 1,130 A1
B 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
C 10,0 gypsum fibre board 0,320 21 1000 1,100 A2
D construction timber (60/..; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
G vapour barrier sd≥ 4m 1000
H spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I - variable insulation material or air layer in type 02
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropi10b-00 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
289,0 e=625 60 from inside
60 from outside
0,20 adequate 52 (-3,-8) 28,24 69,5
awropi10b-01 D
E
H
I
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
249,0 e=625 60 from inside
60 from outside
0,24 adequate 51 (-3,-8) 25,59 67,0
awropi10b-03 D
E
H
I
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
329,0 e=625 60 from inside
60 from outside
0,17 adequate 53 (-3,-8) 30,88 72,0
awropi10b-04 D
E
H
I
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
369,0 e=625 60 from inside
60 from outside
0,15 adequate 54 (-3,-8) 33,53 74,5
awropi10b-05 D
E
H
I
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
369,0 e=625 60 from inside
60 from outside
0,15 adequate 53 (-3,-8) 33,26 75,1
awropi10b-06 D
E
H
I
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
409,0 e=625 60 from inside
60 from outside
0,13 adequate 54 (-3,-8) 35,91 77,5
awropi10b-07 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
289,0 e=625 60 from inside
60 from outside
0,18 adequate 53 (-3,-8) 50,80 75,6
awropi10b-08 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
289,0 e=625 60 from inside
60 from outside
0,20 adequate 52 (-3,-8) 34,06 72,5
awropi10b-09 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [0,040; R=55]
spruce wood
cellulose fibre [0,040; R=55]
289,0 e=625 60 from inside
60 from outside
0,20 adequate 52 (-3,-8) 21,37 76,5
awropi10b-10 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
289,0 e=625 60 from inside
60 from outside
0,22 adequate 52 (-3,-8) 22,19 69,5
awropi10b-11 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
289,0 e=400 60 from inside
60 from outside
0,21 adequate 52 (-3,-8) 27,83 73,7