Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 10,0 plaster 1,000 10-35 2000 1,130 A1
B 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
C 15,0 fibreboard (MDF) 0,140 11 600 1,700 D
D construction timber (60/..; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F 15,0 OSB (sealed with airtight tape) 0,130 200 600 1,700 D
G spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
H - variable insulation material or air layer in type 02
I 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
I 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropi11a-00 D
E
G
H
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
296,5 e=625 60 from inside
60 from outside
0,19 adequate 52 (-3,-8) 30,42 65,6
awropi11a-01 D
E
G
H
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
256,5 e=625 60 from inside
60 from outside
0,23 adequate 51 (-3,-8) 27,77 63,1
awropi11a-02 D
E
G
H
160,0
160,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
296,5 e=625 ; I=without insulation 60 from inside
60 from outside
0,22 adequate 51 (-3,-8) 27,95 65,1
awropi11a-03 D
E
G
H
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
336,5 e=625 60 from inside
60 from outside
0,16 adequate 53 (-3,-8) 33,07 68,1
awropi11a-04 D
E
G
H
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
376,5 e=625 60 from inside
60 from outside
0,14 adequate 54 (-3,-8) 35,71 70,6
awropi11a-05 D
E
G
H
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
376,5 e=625 60 from inside
60 from outside
0,14 adequate 53 (-3,-8) 35,44 71,2
awropi11a-06 D
E
G
H
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
416,5 e=625 60 from inside
60 from outside
0,13 adequate 54 (-3,-8) 38,09 73,7
awropi11a-07 D
E
G
H
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
296,5 e=625 60 from inside
60 from outside
0,17 adequate 53 (-3,-8) 52,98 71,7
awropi11a-08 D
E
G
H
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
296,5 e=625 60 from inside
60 from outside
0,19 adequate 52 (-3,-8) 36,24 68,7
awropi11a-09 D
E
G
H
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [040; E]
spruce wood
cellulose fibre [040; E]
296,5 e=625 60 from inside
60 from outside
0,19 adequate 52 (-3,-8) 23,55 72,6
awropi11a-10 D
E
G
H
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
296,5 e=625 60 from inside
60 from outside
0,21 adequate 52 (-3,-8) 23,71 66,1
awropi11a-11 D
E
G
H
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
296,5 e=400 60 from inside
60 from outside
0,20 adequate 52 (-3,-8) 30,02 69,8

Last update 02.08.2023/hfa.eco2soft