Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 10,0 plaster 1,000 10-35 2000 1,130 A1
B 50,0 wood wool composite boards 0,090 2-5 370 2,000 B
C 24,0 planking spruce wood 0,120 50 450 1,600 D
D construction timber (60/..; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F 24,0 planking spruce wood 0,120 50 450 1,600 D
G vapour barrier sd≥ 7m 1000
H spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I - variable building material
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropi13a-00 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
314,5 e=625 60 from inside
60 from outside
0,19 adequate 52 (-3,-8) 23,01 71,0
awropi13a-01 D
E
H
I
120,0
120,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
274,5 e=625 60 from inside
60 from outside
0,22 adequate 51 (-3,-8) 20,36 68,5
awropi13a-02 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
314,5 e=625 ; I=without insulation 60 from inside
60 from outside
0,21 adequate 51 (-3,-8) 20,53 70,4
awropi13a-03 D
E
H
I
200,0
200,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
354,5 e=625 60 from inside
60 from outside
0,16 adequate 53 (-3,-8) 25,65 73,5
awropi13a-04 D
E
H
I
240,0
240,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
394,5 e=625 60 from inside
60 from outside
0,14 adequate 54 (-3,-8) 28,30 76,0
awropi13a-05 D
E
H
I
200,0
200,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
394,5 e=625 60 from inside
60 from outside
0,14 adequate 53 (-3,-8) 28,03 76,5
awropi13a-06 D
E
H
I
240,0
240,0
80,0
80,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
434,5 e=625 60 from inside
60 from outside
0,13 adequate 54 (-3,-8) 30,67 78,0
awropi13a-07 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
314,5 e=625 60 from inside
60 from outside
0,17 adequate 53 (-3,-8) 45,56 77,1
awropi13a-08 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
314,5 e=625 60 from inside
60 from outside
0,19 adequate 52 (-3,-8) 28,83 74,0
awropi13a-09 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
cellulose fibre [0,040; R=55]
spruce wood
cellulose fibre [040; E]
314,5 e=625 60 from inside
60 from outside
0,19 adequate 52 (-3,-8) 16,13 78,0
awropi13a-10 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
314,5 e=625 60 from inside
60 from outside
0,20 adequate 52 (-3,-8) 16,95 71,0
awropi13a-11 D
E
H
I
160,0
160,0
40,0
40,0
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
314,5 e=400 60 from inside
60 from outside
0,19 adequate 52 (-3,-8) 22,60 75,1

Last update 02.08.2023/hfa.eco2soft