Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B wood-fibre insulation board [055; 200] 0,055 5-7 200 2,100 E
C 12,0 OSB 0,130 200 600 1,700 D
D construction timber (60/..; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F 15,0 OSB 0,130 200 600 1,700 D
G vapour barrier sd≥ 10m 1000
H spruce wood cross battens (a=400) or battens offset) 0,120 50 450 1,600 D
I - variable building material
J 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
J 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) OI3Kon m [kg/m²]
awropi17a-00 B
D
E
H
I
60,0
160,0
160,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
306,5 e=625 60 from inside
30 from outside
0,17 adequate 52 (-3,-10) 26,99 69,7
awropi17a-01 B
D
E
H
I
60,0
120,0
120,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
266,5 e=625 60 from inside
30 from outside
0,20 adequate 51 (-3,-10) 24,47 67,2
awropi17a-02 B
D
E
H
I
60,0
160,0
160,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
air layer
306,5 e=625 ; I=without insulation 60 from inside
30 from outside
0,19 adequate 51 (-3,-10) 24,72 69,1
awropi17a-03 B
D
E
H
I
60,0
200,0
200,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
346,5 e=625 60 from inside
30 from outside
0,15 adequate 53 (-3,-10) 29,51 72,2
awropi17a-04 B
D
E
H
I
60,0
240,0
240,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
386,5 e=625 60 from inside
30 from outside
0,13 adequate 54 (-3,-10) 32,03 74,7
awropi17a-05 B
D
E
H
I
60,0
200,0
200,0
80,0
80,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
386,5 e=625 60 from inside
30 from outside
0,13 adequate 53 (-3,-10) 31,76 75,2
awropi17a-06 B
D
E
H
I
60,0
240,0
240,0
80,0
80,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
426,5 e=625 60 from inside
30 from outside
0,12 adequate 54 (-3,-10) 34,28 77,7
awropi17a-07 B
D
E
H
I
60,0
160,0
160,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [035; 50; <1000°C]
spruce wood
mineral wool [035; 50; <1000°C]
306,5 e=625 60 from inside
30 from outside
0,16 adequate 53 (-3,-10) 52,32 75,8
awropi17a-08 B
D
E
H
I
60,0
160,0
160,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [038; ≥33; ≥1000°C]
spruce wood
mineral wool [038; ≥33; ≥1000°C]
306,5 e=625 60 from inside
30 from outside
0,18 adequate 52 (-3,-10) 29,51 76,8
awropi17a-09 B
D
E
H
I
60,0
160,0
160,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
cellulose fibre [0,040; R=55]
spruce wood
cellulose fibre [040; E]
306,5 e=625 60 from inside
30 from outside
0,17 adequate 52 (-3,-10) 29,51 76,7
awropi17a-10 B
D
E
H
I
60,0
160,0
160,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
sheep wool [0,041; R=26]
spruce wood
sheep wool [0,041; R=26]
306,5 e=625 60 from inside
30 from outside
0,18 adequate 52 (-3,-10) 18,12 69,7
awropi17a-11 B
D
E
H
I
60,0
160,0
160,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
306,5 e=400 60 from inside
30 from outside
0,18 adequate 52 (-3,-10) 26,66 73,9
awropi17a-12 B
D
E
H
I
40,0
160,0
160,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
286,5 e=625 60 from inside
30 from outside
0,18 adequate 52 (-3,-10) 21,27 64,7
awropi17a-13 B
D
E
H
I
100,0
160,0
160,0
40,0
40,0
wood-fibre insulation board [055; 200]
construction timber
mineral wool [040; ≥16; <1000°C]
spruce wood
mineral wool [040; ≥16; <1000°C]
346,5 e=625 60 from inside
30 from outside
0,15 adequate 53 (-3,-10) 38,43 79,7

Last update 23.08.2017/hfa.plb