Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 10,0 plaster 1,000 10-35 2000 1,130 A1
B 50,0 Heraklith BM [095; 570] 0,095 2-5 570 2,100 B
C 16,0 particleboard P5 0,130 50-100 700 1,700 D
D construction timber (60/..; e=625) 0,120 50 450 1,600 D
E - variable insulation material
F 22,0 spruce wood scattered formwork (22/100; e=500) 0,120 50 450 1,600 D
G vapour barrier sd≥ 9m 1000
H 50,0 Heraklith BM [095; 570] 0,095 2-5 570 2,100 B
I 15,0 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropi21a-00 D
E
160,0
160,0
construction timber
mineral wool Klemmplatte KP [038; 30, ≥1000°C]
323,0 60 from inside
60 from outside
0,22 adequate 51 (-4,-12) 34,93 82,2
awropi21a-01 D
E
120,0
120,0
construction timber
mineral wool Klemmplatte KP [038; 30, ≥1000°C]
283,0 60 from inside
60 from outside
0,27 adequate 48 (-5,-13) 32,05 79,0
awropi21a-02 D
E
200,0
200,0
construction timber
mineral wool Klemmplatte KP [038; 30, ≥1000°C]
363,0 60 from inside
60 from outside
0,19 adequate 52 (-3,-12) 37,82 85,3
awropi21a-03 D
E
240,0
240,0
construction timber
mineral wool Klemmplatte KP [038; 30, ≥1000°C]
403,0 60 from inside
60 from outside
0,16 adequate 53 (-3,-11) 40,71 88,4

Source: Knauf Insulation GmbH

Last update 22.12.2025/hfa.plb