Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 Plaster „weberpas topdry“ 0,450 10-35 1600 1,130 A2
B 100,0 s'<15MN/m³ 0,040 1 100 1,030 A1
C 12,5 Rigips Riduro 0,250 4-10 1000 1,050 A2
D 120,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E ISOVER Ultimate 0,035 1 20 1,030 A1
F vapour barrier sd≥ 14m
G 12,5 Rigips Riduro 0,250 4-10 1000 1,050 A2
H 50,0 RigiProfil >50mm; resilient channel
I 50,0 mineral wool [040; 11; <1000°C] 0,040 1 11 1,030 A1
J 12,5 Rigips Riduro 0,250 4-10 1000 1,050 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropi29a-00 E 120,0 ISOVER Ultimate 314,5 60 from inside
90 from outside
0,14 adequate 58 86,94 72,7

Source: Saint-Gobain Austria GmbH

Last update 02.08.2023/hfa.eco2soft