Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 60,0 wood-fibre insulation board WF-PT [048; 180] 0,048 5-7 180 2,100 E
C 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
D - variable insulation material
E 8,0 Funderplan Biofaser (sealed with airtight tape) 0,180 185 1000 1,700 D
F 40,0 spruce wood battens vertical 0,120 50 450 1,600 D
G - variable building material
H 15,0 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 15,0 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropi32a-00 D
G
160,0
40,0
Cellulose fibre [039; 50]
Wood fibre insulation [039; 45]
290,0 60 from inside
60 from outside
0,17 adequate 43 (-1,-6) 27,95 58,7
awropi32a-01 D
G
160,0
40,0
Cellulose fibre [039; 50]
air layer
290,0 60 from inside
60 from outside
0,19 adequate 42 (-1,-6) 26,51 57,2
awropi32a-02 D
G
160,0
40,0
Wood fibre insulation [039; 45]
Wood fibre insulation [039; 45]
290,0 60 from inside
60 from outside
0,17 adequate 43 (-1,-6) 29,22 58,0
awropi32a-03 D
G
160,0
40,0
mineral wool [040; ≥16; <1000°C]
mineral wool [040; ≥16; <1000°C]
290,0 60 from inside
60 from outside
0,17 adequate 43 (-1,-6) 34,51 52,8

Source: FunderMax GmbH