Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 4,0 plaster 1,000 10-35 2000 1,130 A1
B - variable building material
C 15,0 gypsum fibre board 0,320 21 1000 1,100 A2
D construction timber (60/..; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F vapour barrier sd≥ 13m 1000
G 12,5 gypsum fibre board or 0,320 21 1000 1,100 A2
G 12,5 gypsum plaster board type DF 0,250 10 800 1,050 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropo01a-00 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
239,0 e=625 30 from inside
30 from outside
0,20 adequate 44 (-2,-6) 24,33 42,7
awropo01a-01 B
D
E
50,0
120,0
120,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
199,0 e=625 30 from inside
30 from outside
0,25 adequate 43 (-2,-6) 21,68 40,2
awropo01a-02 B
D
E
50,0
200,0
200,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
279,0 e=625 30 from inside
30 from outside
0,17 adequate 45 (-2,-6) 26,97 45,2
awropo01a-03 B
D
E
50,0
240,0
240,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
319,0 e=625 30 from inside
30 from outside
0,15 adequate 46 (-2,-6) 29,62 47,7
awropo01a-04 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [035; 50; <1000°C]
239,0 e=625 30 from inside
30 from outside
0,19 adequate 45 (-2,-6) 42,49 47,7
awropo01a-05 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [038; ≥33; ≥1000°C]
239,0 e=625 60 from inside
60 from outside
0,20 adequate 44 (-2,-6) 29,01 45,2
awropo01a-06 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
cellulose fibre [040; E]
239,0 e=625 30 from inside
30 from outside
0,20 adequate 44 (-2,-6) 18,79 48,4
awropo01a-07 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
sheep wool [0,041; R=26]
239,0 e=625 30 from inside
30 from outside
0,22 adequate 44 (-2,-6) 19,45 42,7
awropo01a-08 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
239,0 e=400 30 from inside
30 from outside
0,22 adequate 44 (-2,-6) 23,92 46,9
awropo01a-09 B
D
E
160,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
349,0 e=625 30 from inside
30 from outside
0,13 adequate 44 (-2,-6) 34,73 44,6
awropo01a-10 B
D
E
50,0
160,0
160,0
Elasticized polystyrene FS
construction timber
mineral wool [040; ≥16; <1000°C]
239,0 e=625; 30 from inside
30 from outside
0,20 adequate 47 (-2,-6) 24,69 42,7

Last update 02.08.2023/hfa.eco2soft