Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 4,0 plaster 1,000 10-35 2000 1,130 A1
B - variable building material
C 15,0 OSB 0,130 200 600 1,700 D
D construction timber (60/160; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F 15,0 OSB 0,130 200 600 1,700 D
G vapour barrier sd≥ 23m 1000
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropo12a-00 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
256,5 e=625 60 from inside
30 from outside
0,20 adequate 44 (-2,-6) 27,58 45,4
awropo12a-01 B
D
E
50,0
120,0
120,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
216,5 e=625 60 from inside
30 from outside
0,24 adequate 43 (-2,-6) 24,94 42,9
awropo12a-02 B
D
E
50,0
200,0
200,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
296,5 e=625 60 from inside
30 from outside
0,17 adequate 45 (-2,-6) 30,23 47,9
awropo12a-03 B
D
E
50,0
240,0
240,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
336,5 e=625 60 from inside
30 from outside
0,15 adequate 46 (-2,-6) 32,88 50,4
awropo12a-04 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [035; 50; <1000°C]
256,5 e=625 60 from inside
30 from outside
0,18 adequate 45 (-2,-6) 45,75 50,4
awropo12a-05 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [038; ≥33; ≥1000°C]
256,5 e=625 60 from inside
30 from outside
0,20 adequate 44 (-2,-6) 32,27 47,9
awropo12a-06 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
cellulose fibre [0,040; R=55]
256,5 e=625 60 from inside
30 from outside
0,20 adequate 44 (-2,-6) 22,05 54,0
awropo12a-07 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
sheep wool [0,041; R=26]
256,5 e=625 60 from inside
30 from outside
0,21 adequate 44 (-2,-6) 22,71 45,4
awropo12a-08 B
D
E
50,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
256,5 e=400 60 from inside
30 from outside
0,21 adequate 44 (-2,-6) 27,18 49,6
awropo12a-09 B
D
E
160,0
160,0
160,0
Polystyrene EPS-F [0,040]
construction timber
mineral wool [040; ≥16; <1000°C]
366,5 e=625 60 from inside
30 from outside
0,13 adequate 44 (-2,-6) 37,99 47,3
awropo12a-10 B
D
E
50,0
160,0
160,0
Elasticized polystyrene FS
construction timber
mineral wool [040; ≥16; <1000°C]
256,5 e=625 60 from inside
30 from outside
0,20 adequate 47 (-2,-6) 27,94 45,4

Last update 02.08.2023/hfa.eco2soft