Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B wood-fibre insulation board WF-PT [045; 180] 0,045 5-7 180 2,100 E
C 24,0 planking spruce wood 0,120 50 450 1,600 D
D construction timber (60/..; e=*) 0,120 50 450 1,600 D
E - variable insulation material
F 24,0 planking spruce wood 0,120 50 450 1,600 D
G vapour barrier sd≥ 6m 1000
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Note Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropo21a-00 B
D
E
60,0
160,0
160,0
wood-fibre insulation board WF-PT [045; 180]
construction timber
mineral wool [040; ≥16; <1000°C]
287,5 e=625 60 from inside
60 from outside
0,19 adequate 51 (-3,-9) 27,66 73,2
awropo21a-02 B
D
E
60,0
200,0
200,0
wood-fibre insulation board WF-PT [045; 180]
construction timber
mineral wool [040; ≥16; <1000°C]
327,5 e=625 60 from inside
60 from outside
0,17 adequate 52 (-3,-9) 30,31 75,7
awropo21a-03 B
D
E
60,0
240,0
240,0
wood-fibre insulation board WF-PT [045; 180]
construction timber
mineral wool [040; ≥16; <1000°C]
367,5 e=625 60 from inside
60 from outside
0,15 adequate 53 (-3,-9) 32,96 78,2
awropo21a-04 B
D
E
60,0
160,0
160,0
wood-fibre insulation board WF-PT [045; 180]
construction timber
mineral wool [035; 50; <1000°C]
287,5 e=625 60 from inside
60 from outside
0,18 adequate 52 (-3,-9) 45,83 78,2
awropo21a-05 B
D
E
60,0
160,0
160,0
wood-fibre insulation board WF-PT [045; 180]
construction timber
mineral wool [038; ≥33; ≥1000°C]
287,5 e=625 60 from inside
90 from outside
0,19 adequate 51 (-3,-9) 32,35 75,7
awropo21a-06 B
D
E
60,0
160,0
160,0
wood-fibre insulation board WF-PT [045; 180]
construction timber
cellulose fibre [0,040; R=55]
287,5 e=625 60 from inside
60 from outside
0,19 adequate 51 (-3,-9) 22,13 78,9
awropo21a-07 B
D
E
60,0
160,0
160,0
wood-fibre insulation board WF-PT [045; 180]
construction timber
sheep wool [0,041; R=26]
287,5 e=625 60 from inside
60 from outside
0,21 adequate 51 (-3,-9) 22,79 73,2
awropo21a-08 B
D
E
60,0
160,0
160,0
wood-fibre insulation board WF-PT [045; 180]
construction timber
mineral wool [040; ≥16; <1000°C]
287,5 e=400 60 from inside
60 from outside
0,20 adequate 51 (-3,-9) 27,26 77,4
awropo21a-10 B
D
E
100,0
160,0
160,0
wood-fibre insulation board WF-PT [045; 180]
construction timber
mineral wool [040; ≥16; <1000°C]
327,5 e=625 60 from inside
90 from outside
0,17 adequate 52 (-3,-9) 33,19 83,2

Last update 02.08.2023/hfa.eco2soft