Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration
timber frame construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 80,0 MW-PT [040; 150] 0,040 1 150 1,030 A1
C 12,5 gypsum fibre board 0,320 21 1000 1,100 A2
D 240,0 construction timber (60/240; e=625) 0,120 50 450 1,600 D
E - variable insulation material
F vapour barrier sd≥ 2m 1000
G 36,0 gypsum plaster board type DF (2x18 mm) or 0,250 10 800 1,050 A2
G 36,0 gypsum fibre board (2x18 mm) 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropo23b-00 E 240,0 mineral wool [040; 30; ≥1000°C] 375,5 60/K₂60 from inside
60 /K₂60 from outside
0,13 adequate 59 (-2,-8) 65,85 84,2

Last update 02.08.2023/hfa.eco2soft