Skip to main content
Regional validity

Scope

timber frame construction
Cross-section of standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­klasse EN
λ μ min – max ρ c
A 7,0 plaster 1,000 10-35 2000 1,130 A1
B 100,0 0,040 1 100 1,030 A1
C 15,0 OSB 0,130 200 600 1,700 D
D 200,0 construction timber (60/200; e=625) 0,120 50 450 1,600 D
E - variable insulation material
F 15,0 OSB 0,130 200 600 1,700 D
G vapour barrier sd≥ 14m
H 12,5 gypsum plaster board type DF or 0,250 10 800 1,050 A2
H 12,5 gypsum fibre board 0,320 21 1000 1,100 A2

Variations of building components

Thickness of layer Fire performance Thermal performance Acoustic performance Eco Sustainability Mass
Thickness [mm] Building material Σ REI U [W/(m²K)] Diffusion Rw (C,Ctr) [dB] ΔOI3 m [kg/m²]
awropo27a-00 E 200,0 mineral wool [040; 30; ≥1000°C] 349,5 60 from inside
90 from outside
0,14 adequate 47 (-4,-9) 57,57 57,7
awropo27a-01 E 200,0 Wood fibre insulation [039; 45] 349,5 60 from inside
90 from outside
0,14 adequate 47 (-4,-9) 51,05 60,4
awropo27a-02 E 200,0 Cellulose fibre [040; 50] 349,5 60 from inside
90 from outside
0,14 adequate 47 (-4,-9) 49,45 61,3

Last update 02.08.2023/hfa.eco2soft