Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside 90
maximum ceiling height = 3 m; maximum load Ed,fi = 80,21 kN/m  
Classified by IBS  
Thermal performance U 0,16 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 63 dB (-7; -16)
Ln,w (Cl)
Assessed by IFT  
Mass per unit area m 96,9 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 19,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 40,0 spruce wood battens (40/60) 0,120 50 450 1,600 D
C vapour-permeable membrane sd ≤ 0,3m
D 160,0 construction timber 60/..; e=625 0,120 50 450 1,600 D
E 160,0 mineral wool [035; 18; <1000°C] 0,035 1 18 1,030 A1
F 100,0 cross laminated timber BBS 0,130 50 470 1,600 D
G 70,0 spruce wood battens (60/60; e=625) mounted on resilient clips 0,120 50 450 1,600 D
H 50,0 mineral wool [040; 18; <1000°C] 0,040 1 18 1,030 A1
I 25,0 gypsum plaster boards Rigips RF (2x12,5 mm) or 0,250 10 900 1,050 A2
I 25,0 gypsum fibre board Rigidur H (2x12,5 mm) 0,350 19 1200 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 44,9
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -70,093 0,233 0,095 4,20e-6 0,014 168,682 1025,676 1194,358 740,677 22,679 763,357

Source: Saint-Gobain Rigips Austria GesmbH

Last update 07.05.2020/hfa.plb