Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall solid wood construction, ventilated, with dry lining, with cladding
Fire performance | REI from inside | 60 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 14,95 kN/m
Classified by IBS
|
||
Thermal performance | U | 0,14 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 63 dB (-7; -16) |
Ln,w (Cl) | ||
Rating by IFT
|
||
Mass per unit area | m | 94,8 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fireklasse EN | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 19,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 40,0 | spruce wood battens (40/60) | 0,120 | 50 | 450 | 1,600 | D |
C | vapour-permeable membrane sd ≤ 0,3m | ||||||
D | 200,0 | construction timber 60/..; e=625 | 0,120 | 50 | 450 | 1,600 | D |
E | 200,0 | mineral wool [035; 18; <1000°C] | 0,035 | 1 | 18 | 1,030 | A1 |
F | 90,0 | cross laminated timber BBS 125 | 0,130 | 50 | 470 | 1,600 | D |
G | 70,0 | spruce wood battens (60/60; e=625) mounted on resilient clips | 0,120 | 50 | 450 | 1,600 | D |
H | 50,0 | mineral wool [040; 18; <1000°C] | 0,040 | 1 | 18 | 1,030 | A1 |
I | 25,0 | gypsum plaster boards Rigips RF (2x12,5 mm) or | 0,250 | 10 | 900 | 1,050 | A2 |
I | 25,0 | gypsum fibre board Rigidur H (2x12,5 mm) | 0,350 | 19 | 1200 | 1,100 | A2 |
Global warming potential | Share of renewable Primary Energy | Resources | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Phase |
GWP-F [kgCO2Äqv.] |
GWP-B [kgCO2Äqv.] |
GWP-T [kgCO2Äqv.] |
PERE [MJ] |
PERM [MJ] |
PERT [MJ] |
PENRE [MJ] |
PENRM [MJ] |
PENRT [MJ] |
AP [kgSO2Äqv.] |
EP [kgPO4Äqv.] |
ODP [kgR11Äqv.] |
POCP [kgEthenÄqv.] |
A1 - A3 | 44,765 | -110,186 | -65,421 | 199,426 | 991,012 | 1190,439 | 734,800 | 21,052 | 755,852 | 0,232 | 0,096 | 4.2194197E-6 | 0,053 |
Source: Saint-Gobain Austria GmbH
Last update 01.02.2024/hfa.plb