Skip to main content
Regional validity

Scope

Building physical assessment

Fire performance REI from inside 60
maximum ceiling height = 3 m; maximum load Ed,fi = 14,95 kN/m  
Classified by IBS  
Thermal performance U 0,21 W/(m2K)
Diffusion adequate
Calculated by HFA  
Acoustic performance Rw (C;Ctr) 45 dB (-1; -7)
Ln,w (Cl)
Assessed by IFT  
Mass per unit area m 79,5 kg/m2
Calculation based on gypsum plaster board type DF GKF
 
solid wood construction
Cross-section of standard configuration

solid wood construction
Standard configuration

Register of building materials used for this application, cross-section (from outside to inside)

Thickness [mm] Building material Thermal performance Reaction to fire­
λ μ min – max ρ c
A 19,0 larch wood external wall cladding 0,155 150 600 1,600 D
B 40,0 spruce wood battens (40/60) 0,120 50 450 1,600 D
C vapour-permeable membrane sd ≤ 0,3m
D 160,0 construction timber (60/..; e=625) 0,120 50 450 1,600 D
E 160,0 mineral wool [035; 18] 0,035 1 18 1,030 A1
F 90,0 cross laminated timber BBS 0,130 50 470 1,600 D
G 15,0 gypsum plaster boards Rigips RF or 0,250 10 900 1,050 A2
G gypsum fibre board Rigidur H 0,350 19 1200 1,100 A2

Ecological rating (per m2 construction area)

Database ecoinvent

ΔOI3 30,5
Calculated by HFA  

Resources
Lifecycle
Phase
GWP
[kg CO2 Äqv.]
AP
[kg SO2 Äqv.]
EP
[kg PO4 Äqv.]
ODP
[kg R11 Äqv.]
POCP
[kg Ethen Äqv.]
PERE
[MJ]
PERM
[MJ]
PERT
[MJ]
PENRE
[MJ]
PENRM
[MJ]
PENRT
[MJ]
A1 - A3 -63,897 0,168 0,072 2,95e-6 0,011 63,092 920,133 983,225 539,860 22,251 562,111

Source: Saint-Gobain Rigips Austria GesmbH