Dieses Bauteil bzw. diese Bauteilvariante ist nicht für den deutschen Gültigkeitsbereich zulässig.
external wall solid wood construction, ventilated, without dry lining, with cladding
Fire performance | REI from inside | 30 |
---|---|---|
maximum ceiling height = 3 m; maximum load Ed,fi = 14,95 kN/m
Classified by IBS
|
||
Thermal performance | U | 0,18 W/(m2K) |
Diffusion | adequate | |
Calculated by HFA
|
||
Acoustic performance | Rw (C;Ctr) | 45 dB (-3; -8) |
Ln,w (Cl) | ||
Assessed by IFT
|
||
Mass per unit area | m | 68,6 kg/m2 |
Calculation based on gypsum plaster board type DF GKF
|
Thickness [mm] | Building material | Thermal performance | Reaction to fire | ||||
---|---|---|---|---|---|---|---|
λ | μ min – max | ρ | c | ||||
A | 19,0 | larch wood external wall cladding | 0,155 | 150 | 600 | 1,600 | D |
B | 40,0 | spruce wood battens (40/60) | 0,120 | 50 | 450 | 1,600 | D |
C | vapour-permeable membrane sd ≤ 0,3m | ||||||
D | 200,0 | construction timber (60/..; e=625) | 0,120 | 50 | 450 | 1,600 | D |
E | 200,0 | mineral wool [035; 18] | 0,035 | 1 | 18 | 1,030 | A1 |
F | 90,0 | cross laminated timber BBS | 0,130 | 50 | 470 | 1,600 | D |
G | gypsum plaster boards Rigips RF or | 0,250 | 10 | 900 | 1,050 | A2 | |
G | gypsum fibre board Rigidur H | 0,350 | 19 | 1200 | 1,100 | A2 |
OI3Kon | -6,1 |
---|---|
Calculated by IBO
|
GWP [kg CO2 Äqv.] |
AP [kg SO2 Äqv.] |
PEI ne [MJ] |
PEI e [MJ] |
EP [kg PO4 Äqv.] |
POCP [kg C2H4 Äqv.] |
---|---|---|---|---|---|
-92,2 | 0,184 | 610,3 | 1.614,6 | 0,030 | 0,044 |
Source: Saint-Gobain Rigips Austria GesmbH
Last update 28.09.2017/hfa.plb